23
v3.1.22
Advanced Operation
CellarPro cooling systems can be programmed with advanced settings to achieve more
control over conditions inside the cellar. Conditions like humidity, the Temperature
Differential, and alarm settings all can be modified for custom applications. To access the
advanced settings, do the following:
Press the “Set” button and the “Down” button together at the same time, and hold for
three seconds. Then, use the “Up” or “Down” button to scroll to the following screen:
HUMIDITY: The factory preset for this setting is “3”.
If the humidity inside the cellar is too low, press the “Set” button, then
use the “Up” button until the desired setting is reached. The
recommended setting is 3.
TEMPERATURE DIFFERENTIAL: The factory preset for this setting is
“4”.
This setting determines the Temperature Differential and therefore the
temperature at which the unit will cycle on. The recommended setting
is 4 unless using a bottle probe in liquid, in which case the
recommended setting is 1.
HIGH TEMPERATURE ALARM: The factory preset for this setting is
“70”.
This setting designates the High temperature inside the cellar at which
the alarm is triggered. We recommend leaving this setting at the
factory preset.
LOW TEMPERATURE ALARM: The factory preset for this setting is “45”.
This setting designates the Low temperature inside the cellar at which
the alarm is triggered. We recommend leaving this setting at the
factory preset.
ENERGY SAVINGS MODE DIFFERENTIAL: The factory preset for this
setting is “4”.
This setting increases or decreases the Temperature Differential for
the Energy Savings Mode. The recommended setting is 4.