Cut the black zip tie
Using a flat head screw driver loosen the six
terminal screws outlined in red, and remove
the wires from the terminals.
Cut the zip tie holding the high and low
pressure wires. Also, remove the black wire
coming from the Johnson Control from
terminal #6. Re-secure the other black wire
back into terminal #6 on the terminal block.
Remove the adhesive backing from the bottom
of the Magnacraft Relay Assembly.