CEL-MAR ADA-1020 Скачать руководство пользователя страница 12

Transmission line

DB9F/DB9M multicore cable  9x0,34 

shielded or  9-pair twisted cable, UTP 

9x2x0,5 (24AWG) shield inside large 

interferences STP 9x2x0,5 (24AWG).

2-pair twisted cable eg UTP 4x2x0,5 

(24AWG), shield inside large 

interferences eg STP 4x2x0,5 (24AWG)

Standards

RS-232C /CCITTV.24

Current Loop 0-20mA +/-20mA

Maximum baud rate

38,4 kbps (depend on line length Current Loop) /19,2kbps (for Current Loop network)

Transmission type 

Current Loop asynchronic half duplex or full duplex

Optical signalisation

PWR – green LED power supply,

RX - red LED data receiving from Current Loop side,

TX - yellow LED data transmission through Current Loop interface

Electrical Parameters

Power requirements

Standard : 10 - 24 – 30 V DC

Option     : 10 - 24 – 48 V DC

Power cable

Recommended length of  power cable < 3m

Power

<3W

Protection from reverse power polarization

YES

Galvanic isolation

1kV= or 3kV= (between power circuit and RS232 signal lines RS-232)

1kV= or 3kV= (between power circuit and Current Loop signal lines)

Optoisolation

~3kV= (between Current Loop signal line and and RS-232)

Electromagnetic compatibility

Resistance to disruptions according to the standard PN-EN 55024.

Emission of disruptions according to the standard PN-EN 55022.

Safety requiring

According to the PN-EN60950 norm.

Environment

Commercial and light industrial.

Environmental Parameters

Operating temperature

-30 ÷ 60°C

Humidity

5 ÷ 95% - non-condensing

Storage temperature

-40 ÷ 70°C

Casing

Dimensions

53 x 90 x 62mm

Material

Noryl UL. 94 V-O

Degree of casing protection

IP40

Degree of terminal protection

IP20

Weight

0,10 kg

According to standards

DIN EN50022, DIN EN43880

Location during work

Free

Mounting method

On the rail compliant with DIN35 / TS35 standard.

12

ADA-1020

Dear Customer,

Thank you for purchasing 

CEL-MAR Company 

product.

We hope that this user manual helped connect and start up the  

ADA-1020 converter.

 We also wish to inform you that we are a

manufacturer of the widest selections of data communications products in the world such as: data transmission converters with

interface RS232, RS485, RS422, USB, Ethernet, Wi-Fi, Current Loop, Fibre-Optic Converters and other.

Please contact us to tell how you like our products and how we can satisfy you present and future expectation.

CEL-MAR sp.j.

Computers Science and Electronic Factory
str Sciegiennego 219C
25-116 Kielce, POLAND

Tel................................................... : +48 41 362-12-46

Tel/fax..............................................: +48 41 361-07-70

Web.................................................: 

http://www.cel-mar.pl

Office...............................................: 

[email protected]

Sales department........................... : 

[email protected]

Technical information ..................... 

[email protected]

Содержание ADA-1020

Страница 1: ...User manual ADA 1020 RS 232 to Current Loop converter 1 io_ada 1020_v3 26_en Copyright 2001 2020 CEL MAR sp j ADA 1020...

Страница 2: ...PORT DTE TYPE COMPUTER 6 3 2 2 CONNECTION OF DEVICES WITH RS232 PORT DCE TYPE MODEM 6 3 3 CONNECTION OF THE CURRENT LOOP INTERFACE DEVICES 7 3 3 1 CONNECTION OF THE CURRENT LOOP LINE TO ADA 1020 CONVE...

Страница 3: ...he supply network is only after disconnecting the power supply circuit voltage Do not carry out the assembly or dis assembly of the device if it is enabled This may result to short circuit and damage...

Страница 4: ...nsmitter of Current Loop 0 20mA can work as ACTIVE or Passive the selection is made by the TX switch on the front panel see Fig 1 The passive transmitter can be used only for creation of current loop...

Страница 5: ...le of adequate cross section due to voltage drops for converter powering not supply converter from power circuit device that generates large impulse interference such as transmitters contactors 3 1 AS...

Страница 6: ...e is shown below Fig 6 DCE type connection of ADA 1020 to device with RS232 interface eg modem 6 ADA 1020 RxD 2 TxD 3 DTR 4 DSR 6 RTS 7 CTS 8 PC SG 5 RS232 DTE DB 9M ADA 1020 Current Loop Vss Vss Powe...

Страница 7: ...ple connection of two ADA 1020 together The line length less than 500m 7 ADA 1020 Current Loop Line 2 pair twisted ADA 1020 Current Loop Vss Vss Power Supply RS232 DCE DB 9F CTS 7 RTS 8 GND 5 Vss Vss...

Страница 8: ...232 INTERFACE DEVICES TO CURRENT LOOP BUS In this case example the Current Loop bus is created by one ADA 1020 converter MASTER active transmitter and one ADA 1020 converter SLAVE active transmitter t...

Страница 9: ...urrent loop receiver of overvoltage arising Current Loop bus The number of the SLAVE converters can be less for long lines Example of connection is shown below 9 ADA 1020 GND RS232 Current Loop Bus MA...

Страница 10: ...roperly green LED PWR on front panel of converter should light if not check polarization of power connection and if RX red LED is lighted check the correctness of connection of the Current Loop transm...

Страница 11: ...VERSIONS ADA 1020 Order example Product Symbol ADA 1020 1 1 2 3 1 Current Loop Voltage 24VDC 1 Current Loop Type 20mA 2 1kV galvanic isolation 3 cover without inlets plug in screw terminal block Power...

Страница 12: ...ssion of disruptions according to the standard PN EN 55022 Safety requiring According to the PN EN60950 norm Environment Commercial and light industrial Environmental Parameters Operating temperature...

Отзывы: