1.2  

Safety and Reference Rules   

The Battery Charger is made in accordance with the following ECC rules: 

2014/35/UE   

Rules for low voltage equipment 

2014/30/UE   

Electromagnetic compatibility 

and products norms EN60335-1 and 60335-2-29. 

Chargers are manufactured under ISO9001 conditions 

 

 

Only certified electricians should arrange the connection of the Charger to AC Mains supply. We suggest you use an 

electrician who is able to issue a declaration of conformity for the work carried out. The declaration must include the 

connection to the earth. the verification of the line. circuit breaker / fuse. switch / isolator. plug / socket and the AC Main. 

Electrical safety is assured only when the plug/ socket is connected to an efficient earthing point. You may request our 

office for our Installation Form. 

 

If your Battery Charger AC plug needs to be replaced.it should be done by a qualified electrician. 

 

Protect the power supply cables with slow fuses or magneto thermal switch / Breaker (D curve)

.  

 

We suggest using power socket with a rotary switch to avoid plug extraction. 

 

Do not disconnect the battery plug before the Battery Charger is switched off by the “Off” Push button located on the door. 

To prevent casual or voluntary disconnection. we suggest the use of mechanical blocks or auxiliary contacts to feed the 

Battery Charger. 

 

Do not open the Battery Charger cabinet / door before checking the power plug is disconnected. the main switch is off and 

the battery is disconnected. 

 

If the AC power cables or the Battery Cables are worn or even if they are partially damage. please have them replacedby a 

qualified electrician. 

 

2. INSTALLATION AND POWERING 

 

Please. read carefully the Chapters above “

Electrical Information

” and “

Safety Rules

”. 

The installation must be made in accordance with the following instructions. The operation must be made in total absence of 

electrical power.     Terms of use: 

-

 

Working temperature and relative humidity: from 0° to 40°C (RH75%) 

-

 

Storage temperature: from -20°C to 60°C 

2.1  

Choosing the place  

 

Put the Battery Charger in a suitable place. allowing adequate ventilation. far from any heat source. 

 

Place the cabinet on a non-flammable surface such as stone. concrete or metal. 

 

Chargers are heavy devices. They must be secured to prevent accidental fall or tipping over. Place them on the ground or 

use robust shelves. 

 

Make sure the Battery Charger front panel with OFF push button has easy access and that charging phase control panel 

(LEDs and Display) are clearly visible. 

 

2.2  

Checking the electrical system line   

 

Ensure the electrical system line has been laid in accordance with related current standards in force. 

 

The electrical connection must be made by qualified electrician. 

We suggest that you use a professional who is in a position to issue a "declaration of conformity"for the job performed. 

 

The electrical safety is guaranteed only when the power plug is correctly connected to an efficient earth/ground. 

 

Check that the electrical mains system can withstand the power of the battery charger (V/A) and that the voltage and 

frequency of the line comply (Volts and Hz) with the rating of the charger. 

 

Make sure the charger is protected with appropriate time delay fuses/circuit breaker. Please refer Section 9. 

 

2.3  

Checking the charger and the battery 

 

 

Check that the input Vac cables, the output battery cables and the battery/charger plugs are in good condition and 

properly insulated. 

WARNING

: charger installation or plugs replacement must be performed by qualified personnel. 

 

Ensure good ground insulation of the battery and the power cables. 

 

Make sure the " polarity " of the battery cables (through the plugs) correspond with the battery charger 

cables. Positive to Positive and Negative to Negative. 

 

Check that the battery is matched to the charger in respect of both voltage (V) and capacity (Ah). 

 

The battery must be ready to be charged. clean and with proper electrolyte level. 

 

 

Содержание 5DTM

Страница 1: ...al 5DTM 5DTT The manual refers to chargers with AT 12 board with FW 6 4L or higher dec 2021 Slightly differences can be found using different versions ADVANCED SMART DERIVATIVE CHARGER with Navigator...

Страница 2: ......

Страница 3: ...arts must be authorised in writing by our technical department Warning this series is only 50Hz the Wa profile is altered if connected to a 60Hz Mains NOTE Measure the site AC voltage during charge an...

Страница 4: ...n total absence of electrical power Terms of use Working temperature and relative humidity from 0 to 40 C RH75 Storage temperature from 20 C to 60 C 2 1 Choosing the place Put the Battery Charger in a...

Страница 5: ...on 5 minutes every hour for the following 15h Stage 4 Conservation 5 minutes every 15 h until the charger is switched off Charge termination dU dt 3 VISUAL INDICATIONS L1 L2 L3 L4 L5 Green Yellow Gree...

Страница 6: ...max F2 End p Idle Battery may be disconnected now Charge ended on achieving absolute maximal Time Par 308 Wait Charge not started yet DELAY START function is set Charger awaits pre set delay hh mm bef...

Страница 7: ...ss Button 3 forward to view the delay time set for example 01 00 Delay start countdown begins Remaining time reduction will be shown for example 00 59 and so on Call up Navigator parameter again and U...

Страница 8: ...Supplying current Stage 2 1 1 End of Charge Battery can be disconnetted and ready to be used 1 Equalisation or Preservation charge Supplying current for 5min 1h Stage 3 and 4 1 1 After starting up th...

Страница 9: ...the main switch of the electric line and the input AC fuses breaker C Battery sulphated D The Mains and the transformer plug are not well matched E The current Ammeter sensor or its connection cables...

Страница 10: ...nnection problem B Check AC mains plug connection the main switch of the electric line and the input AC fuses breaker C Battery sulphated D The Mains and the transformer plug are not well matched E Th...

Страница 11: ...ot be exposed to dust and humidity Clean the Battery Charger Should it be too dirty or damp move it in a safer place The same applies for the battery 6 4 Extraordinary Maintenance Perform maintenance...

Страница 12: ...1 25 3 32 100 7 6 31 7 40 60 4 1 5 6 8 120 9 1 38 0 50 80 5 4 7 5 10 140 10 6 44 3 63 100 6 8 9 4 12 48 160 12 2 50 7 63 120 8 2 11 2 16 140 9 5 13 1 16 160 10 9 15 0 20 180 12 2 16 9 25 220 15 0 18...

Страница 13: ...rev 1904 EX FW 6 4 13 20...

Страница 14: ...low instructions in clause 1 1 03 Battery Plug Socket and AC Main socket BATTERY PLUG SOCKET 1 Check cables polarity of the DC plug socket red positive and black negative both from the battery and fro...

Страница 15: ...ot have signs of scorch acr pitting 3 Check the terminals of the battery cables The terminals must be well tightened 4 Plug socket casing must not be damaged AC MAINS PLUG SOCKET 1 Verify that the cab...

Страница 16: ...th an air blow blower nozzler at least 200mm away or with a dry little brush Do not use wet cloth or similar 03 Cables and terminal examination In general you must ensure all cables are well tightened...

Страница 17: ...hours 12 13 hours Starting Current Amps From 80 discharged state Ah at 5 hour rate 20 110 160 30 165 240 40 220 320 50 275 400 60 330 480 80 440 640 100 550 800 120 660 960 140 770 1 120 160 880 1 28...

Страница 18: ...__ ____________________________________________ ____________________________________________ ____________________________________________ ____________________________________________ _________________...

Страница 19: ......

Страница 20: ......

Отзывы: