PMC-1302 ESG
Ethernet Serial Gateway
User Manual
Version: V1.0A
06/21/2012
Ceiec Electric Technology
Страница 1: ...PMC 1302 ESG Ethernet Serial Gateway User Manual Version V1 0A 06 21 2012 Ceiec Electric Technology...
Страница 2: ...m Ceiec Electric Technology CET The information contained in this Manual is believed to be accurate at the time of publication however CET assumes no responsibility for any errors which may appear her...
Страница 3: ...not accept liability for any damage caused by device malfunctions CET accepts no responsibility for the suitability of the device to the application for which it was purchased Failure to install set...
Страница 4: ...Chassis Ground Wiring 10 Chapter 3 Operating the PMC 1302 ESG 11 3 1 Front Panel LED Indicators 11 3 2 Reset Button 11 3 3 Typical Application 11 Chapter 4 Configuring the PMC 1302 ESG via Web Interf...
Страница 5: ...nterface DIN Rail or Wall Mount Extended operating temperature 1 3 Applications The PMC 1302 ESG supports the efficient transfer of serial packets between the upstream network based applications and t...
Страница 6: ...6 Ceiec Electric Technology Chapter 2 Installation 2 1 Appearance Figure 2 1 Appearance 2 2 Unit Dimensions Figure 2 2 Dimensions...
Страница 7: ...ng holes protrude from the device s body and re install the screws that hold the mounting plates in place The PMC 1302 ESG package comes with four additional mounting screws in a little plastic bag Us...
Страница 8: ...n a RS 485 bus The overall length of the RS 485 cable connecting all devices should not exceed 1200m The following figure illustrates the RS 485 communications connections on the PMC 1302 ESG Figure 2...
Страница 9: ...Brown Pin 8 Brown Figure 2 6 Straight through Connection 2 6 2 Cross over Connection The following figure illustrates the definition of an 8 pin RJ45 cross over cable The wiring sequence from pin 1 to...
Страница 10: ...ve wire to the L terminal and the negative wire to the N terminal Connect the GND terminal to ground Figure 2 8 Power Supply Connections 2 8 Chassis Ground Wiring Installation Connect one end of the g...
Страница 11: ...w Blinking P2 is transmitting data P3 Rx Green Blinking P3 is receiving data P3 Tx Yellow Blinking P3 is transmitting data Table 3 1 LED Indicators 3 2 Reset Button There is a Reset button at bottom o...
Страница 12: ...ars Select the Security tab and then click on the Custom Level button near the bottom of the window The Security Settings window appears Enable the three options as shown below and then click OK 2 The...
Страница 13: ...e confirmed the following page appears 4 2 Basic Settings The Basic Settings page is divided into 3 areas Network Settings P2 Settings and P3 Settings 1 Network Settings P1 The Network Settings for th...
Страница 14: ...k up of the IP connection at the PMC 1302 ESG if the application software fails to close the IP connection for some unknown reasons It is recommended that the default Timeout of 300 seconds be used It...
Страница 15: ...nd pane and the following screen appears on the right hand pane Click on the Restart button to save your changes into memory After restart the user needs to re enter the user name and password to log...
Страница 16: ...IP address for P1 is 192 168 0 127 5 2 Configuring the PMC 1302 ESG To configure the PMC 1302 ESG the user can log on to its Web Console page via the Internet Explorer by entering the IP address of th...
Страница 17: ...those of the PMC 660V1 2 The IP Port Number for P2 is 20000 After the P2 settings of the PMC 1302 ESG has been correctly configured click Restart menu item on the left hand pane to open the page and t...
Страница 18: ...ve Type MODBUS RTU Protocol Master Site Driver 2 Polling Mode Serial 3 Port Type Ethernet 4 IP 192 168 0 127 5 Port 20000 for P2 of PMC 1302ESG Select PMC 660 on the right hand pane under the Device N...
Страница 19: ...ick Import SNF file and then select the appropriate SNF file from the pop up dialog box Click on the Save icon on the Tool Bar to save the current configuration into PecStar s database The PecStar sof...
Страница 20: ...P3 Green Blinking Receiving activity Tx P2 P3 Yellow Blinking Transmitting activity Protocol Protocol TCP UDP HTTP Power Supply L N Standard Burden 95 250VAC DC 47 440Hz 3W Protection ESD Protection...
Страница 21: ...elds IEC 61000 4 3 2008 Level III Fast Transients IEC 61000 4 4 2004 Level IV Surges IEC 61000 4 5 2005 Level IV Conducted Disturbances IEC 61000 4 6 2008 Level III Magnetic Fields IEC 61000 4 8 2009...
Страница 22: ...us Ceiec Electric Technology Headquarters 8 F Westside Building 201 Terra Industrial Tradepark Che Gong Miao Shenzhen Guangdong P R China 518040 Tel 86 755 8341 5187 Fax 86 755 8341 0291 Email suppor...