4
Description
FI100K0025v1100 UK - - PD240CH
1.3
Controls and Indicators
Optical alarm indicator
RED: metal mass alarm
During start-up it provides further indications.
Battery level
indicator
OFF: battery life
>1h (approx.)
Blinking: low
battery
Steadily lit:
battery discharged
Selection of the
acoustic alarm
signal
Press to enable
(inner lamp on) or
disable (inner lamp
off) the alarm
indication.
Alarm buzzer
Selection of the
vibrating alarm
signal
Press to enable
(inner lamp on) or
disable (inner lamp
off) the alarm
indication.
Analysis Mode
selection
Press the proper
push button.
Head: high sensitivity
to very small magnetic
metals. Insensitive to
medium size
nonmagnetic metal
items
Body: high sensitivity to
small magnetic metals.
Insensitive to large
nonmagnetic metal
items
All-metals: high
sensitivity to all types
of metals
ON/OFF switch
Press to turn the device on.
Keep pressed for at least 3 seconds to
switch the device off.
Press briefly to display the current state of
the device and/or to reset a continuous
alarm.
1.4 Marking
Equipment marking is located in the lower side,
near the handle.
The data provided are as follows:
model
serial number (SN)
power supply voltage and consumption
battery type and quantity
PD240CH
SN xxxxxxxxxxx
3V 370mW
Battery Size AA or LR6 x2