background image

ISSUE 4.0 

CEECO 

Communication Equipment & Engineering Company 

PROPRIETARY

 

7

PROGRAMMING CONTINUED 

 

3.9

 

When you are 

finished

 programming, 

press the “CALL & HANGUP” 

button

 to hang up the phone.  Return the two plastic 

mini-jumpers

 to the 

“OFF”

 or outermost position, as depicted on the last page of this manual.  

Secure the telephone assembly in the housing.  The phone is now ready for 
use. 

 
 

  

4.0 OPERATION 

 

To receive a call, press the "EMER/CALL" button located on the front of the 
phone, when the telephone rings. The LED (if provided) will illuminate red at this 
time.  In order to receive incoming calls the phone must have been programmed 
with a “1” under Digit 2 in section 3.8 of this manual.  During ringing, the LED 
will flash red and green to indicate such.  When the call is answered, a normal 
speakerphone conversation may take place, and the LED will shine GREEN. 
After the call is complete, press the "EMER/CALL" button on the front of the 
panel again to hang up the phone.  If the user does not press the button on the 
front of the panel when he or she is finished using the phone, then the phone will 
hang up after detecting a wink (open switch interval) or the timer times out.  
 
If the telephone has been mated with external call equipment, a call may also be 
initiated by pressing the “EMER/CALL” button.  The LED (if provided) will 
illuminate red at this time.  During ringing, the LED will flash red and green to 
indicate such.  The external call equipment should direct the call as intended and a 
normal speakerphone conversation may take place. The LED will shine GREEN 
at this time.  After the call is complete, press the "EMER/CALL" button on the 
front of the panel again to hang up the phone.  If the user does not press the button 
on the front of the panel when he or she is finished using the phone, then the 
phone will hang up after detecting a wink (open switch interval) or the timer times 
out.  
  

 
 

5.0  RECOMMENDED TOOLS AND TEST EQUIPMENT 

 

DTMF Test Set             
Volt/Ohm Meter 
CEECO Security Tool, 301-064 

Содержание SSP-511-X-ADA

Страница 1: ...RGENCY WEATHERPROOF TELEPHONE OR MODEL SSP 511 X ADA HANDS FREE STAINLESS STEEL PANEL TELEPHONE EQUIPPED WITH SPK1 07UNVLr3FIRMWARE Serving the Telephone Industry Since 1930 Communication Equipment 51...

Страница 2: ...g CEECO for assistance MODEL NUMBER MODEL WPP 531 X ADA OR SSP 511 X ADA EQUIPPED WITH SPK1 07UNVLr3 FIRMWARE SERIAL NUMBER DATE MANUFACTURED LOCATION INSTALLED For us to better serve you please have...

Страница 3: ...AL 4 3 0 PROGRAMMING 5 PROGRAMMING CONTINUED 6 PROGRAMMING CONTINUED 7 4 0 OPERATION 7 5 0 RECOMMENDED TOOLS AND TEST EQUIPMENT 7 6 0 INSTALLATION NOTES AND ASSEMBLY INSTRUCTIONS 8 7 0 TESTING 10 8 0...

Страница 4: ...X ADA Hands Free Weatherproof telephone is a sturdy vandal resistant stainless steel speakerphone Instead of a hookswitch and handset the WPP 531 X has a Press to start Press to stop button for initi...

Страница 5: ...tion is accessed by dialing the sign and the two digit code which corresponds to that location The only valid program locations for this phone is 00 The previous contents of the location are automatic...

Страница 6: ...git 4 Always 0 for this model Digit 5 Always 1 for this model Digit 6 0 Steady red LED no call progress indication 9 Activate ADA feature call progress LED Digit 7 Always 0 for this model Digit 8 Alwa...

Страница 7: ...EMER CALL button on the front of the panel again to hang up the phone If the user does not press the button on the front of the panel when he or she is finished using the phone then the phone will han...

Страница 8: ...tection circuitry 6 5 The use of a gas tube station protector is recommended The station ground should not exceed 50 ohms 6 6 Plug the modular line cord from the faceplate assembly into the RJ11C term...

Страница 9: ...ISSUE 4 0 CEECO Communication Equipment Engineering Company PROPRIETARY 9 6 9 OVER VOLTAGE PROTECTION DIAGRAM...

Страница 10: ...l time out occurs Action If the telephone has been mated with external call equipment press the EMER CALL button to initiate a call The LED is red Reaction The external call equipment directs the call...

Страница 11: ...0 non condensating PROGRAMMING Via DTMF keypad MEMORY RETENTION Non volatile memory retention DIMENSIONS 7 1 6 wide x 11 1 4 high x 4 1 4 deep SSP handset on hook MOUNTING Vertical surface mount WEIGH...

Страница 12: ...018 MODULAR LINE CORD 1 531 11075 FACE PLATE 1 301 054 MODULAR CONNECTOR RJ11C 1 700 008 KEYPAD CABLE 1 660 000 CEECO SPK BOARD 1 705 110 CONNECTORIZED KEYPAD 1 14067 MICROPHONE 1 6020 MOMENTARY PANE...

Страница 13: ...one Network through a registered jack provided by the Telephone Company in your area This jack is a modular outlet which you can order from your local telephone company 10 3 NOTIFICATION TO THE TELEPH...

Страница 14: ...to the defective unit This information must be inside the shipping container 11 2 DIRECT ALL INQUIRES TO CEECO Repair Department 519 West South Park Street Okeechobee FL 34972 863 357 0798 863 357 00...

Страница 15: ...eplacement of any part found to be defective by CEECO Under no circumstances shall CEECO be liable for loss damage cost of repair or consequential damages of any kind which have been caused by neglect...

Страница 16: ...hen programming is completed move the mini jumpers to the OFF position NOTE Do not leave the mini jumpers in the ON position this will decrease battery life MOVE THE MINI JUMPERS TO THE ON POSITION BE...

Отзывы: