6.0 INSTALLATION NOTES AND ASSEMBLY INSTRUCTIONS
6.1
Using a 301-064 security tool (sold separately), loosen and remove the
security screws.
6.2
The security tool is for a standard 5/32" button head screw generally used
on the framework of the phone booths.
6.3
Separate the faceplate assembly from the weatherproof housing by pulling
the faceplate forward.
6.4
Run the inside station wire into the enclosure and terminate on the RJ11C
terminal block inside, as depicted on the following page. The CEECO
provided terminal block (jack)
must
be used, as it contains required over-
voltage protection circuitry.
6.5
The use of a gas tube station protector is recommended. The station
ground should not exceed 50 ohms.
6.6
Plug the modular line cord from the faceplate assembly into the RJ11C
terminal block.
6.7
Dress the telephone line cord and AC cable away from the security screws
and seat the faceplate into the weatherproof housing.
6.8
Secure the cover assembly by tightening the security screws.
*****WARNING*****
A.
Never install telephone wiring during a lightning storm.
B.
The telephone must be grounded in accordance with local
and national electric codes.
C.
Never install telephone jacks in wet locations unless the jack
is specifically designed for wet locations.
D.
Never touch uninsulated telephone wires or terminals unless
the telephone line has been disconnected at the network
interface.
E.
Use caution when installing or modifying telephone lines.