![CEECO SSP-511-F Скачать руководство пользователя страница 6](http://html1.mh-extra.com/html/ceeco/ssp-511-f/ssp-511-f_service-manual_2578864006.webp)
ISSUE 4.0
CEECO
Communication Equipment & Engineering Company
PROPRIETARY
6
PROGRAMMING CONTINUED…
Be sure to record your selections below for future reference.
#00 0 __ __ __ 0 __ 0 __ 0 __
Digit 1:
0
Always 0
for this model
Digit 2:
0
No incoming calls allowed.
1
Incoming calls allowed.
Digit 3:
0
Always 0
for this model
.
Digit 4:
0
No Time Out Feature On Speed Dialing
1 -9
Minutes for Time Out for Speed Dialing
Digit 5:
0
Always 0
for this model.
Digit 6:
1
Always 1
for this model.
Digit 7:
0
Always 0
for this model.
Digit 8:
0
Do Not Dial PBX number in Location #91
1
Dial PBX number in Location #91
Digit 9:
0
Always 0
for this model.
Digit 10:
0
No Wink Detect
1-9
Length of the Wink (l = 50ms incremental to 450ms.
5
is recommended)