Issue 4.0
CEECO
Communication Equipment and Engineering Company
PROPRIETARY
9
3.12 If you have a DTMF test set and you want to inspect any memory location you
must have location #00 digit 4 set to a "1". Then simply enter the # key followed
by the two digit code for the memory location to be inspected. The information
stored in that memory location should appear on your test set.
3.13 To change a single memory location, place the phone on hook and place the two
mini-jumpers in the "ON" position. Take the phone off hook, enter # plus the
corresponding two digit code for that memory location, and enter the new
numbers. Hang the phone up and place the two mini-jumpers in the "OFF"
position.
3.14 Summary of programming locations:
LOCATION
DESCRIPTION
SAMPLE ENTRY
#00
Option
Number 10110000
#18
Default
Call
Processor 555-1212
#19
P.B.X. Access Code
9
#20
Phone I.D. Number
1234567
#21 - #29
Card Protocol Code
3
#30 - #49
Speed Dial Numbers
444-4444
#51 - #59
Card Type Identifiers
660015
#61 - #69
POP Numbers For Each Card Type 950-5555
#70 - #79
Free Call Index
911
#97
Clear All Programmable Memory N/A
4.0 PROGRAMMING
TABLES
4.0
OPTION
TABLE
CODE
DESCRIPTION
#00 _ _ _ _ _ _ _ _ _
Digit 1 2 3 4 5 6 7 8 9
PROGRAMMING TABLES CONTINUED
4.2 IDENTIFICATION
TABLE