Issue 4.0
CEECO
Communication Equipment and Engineering Company
PROPRIETARY
7
PROGRAMMING CONTINUED
Be sure to record the Protocol numbers entered from the previous page into the Protocol
table locations #21-#29 on page 10 for future reference. Also record the Card Type
Identifiers in the Card Type Identifier Table locations #51-#59. When entering numbers
in the Card Type Identifier table, if you are using identifiers that have similar beginning
digits, you must enter them according to their digit length. Place the longer length
numbers first. Record the POP numbers in the POP Table locations #61- #69.
EXAMPLES
:
WRONG
WRONG
DIGIT LENGTH
DIGIT LENGTH
Loc. |1|2|3|4|5|6|7|
|1|2|3|4|5|6|7|
#51
|8|5|5| | | | |
AT&T
|8|5|5| | | | |
AT&T
#52
|6|6|0|0| | | |
ALL BOCS
|6|6|0|0|3|0| | ITT
#53
|6|6|0|0|3|0| | ITT
|6|6|0|0|3|2| | MCI
#54
|6|6|0|0|3|2| | MCI
|6|6|0|0| | | |
ALL BOCS
#55 |6|6|0|0|1|5| | WIS BELL
|6|6|0|0|1|5| | WIS BELL
Similar beginning digits.
Similar beginning digits.
RIGHT
DIGIT
LENGTH
Loc. |1|2|3|4|5|6|7|
#51
|8|5|5| | | | |
AT&T
#52
|6|6|0|0|3|0| | ITT
#53
|6|6|0|0|3|2| | MCI
#54
|6|6|0|0|1|5| | WIS BELL
#55 |6|6|0|0| | | |
ALL BOCS
Similar beginning digits.
The first example is wrong because location 52 would cause the phone to match ITT,
MCI and WIS BELL with the protocol for all BOCS. The second example is wrong
because location 54 would cause the phone to match a WIS BELL card to the protocol
for all other BOC cards. Notice, in the last example, that even though the AT&T number,
in location 51, is shorter then the numbers that follow it the right protocol is selected
because the beginning digits are different.
Be sure that you adjust the other tables if you have already entered data in them.