11. Blanking
The TOFniva is available with and without a blanking function. Versions that features blanking trigger the output when
objects are dynamic (moving) within the detection field. Static objects within the detection field will be ignored and
blanked out (after 30 seconds). This covers with objects that are already present at power up (i.e. bollards).
Start-up:
Figure 8:
Active blanking - start-up sequence
with i.e. bollards.
Active blanking:
Figure 10:
The detection field is free.
12. Trouble shooting
If the problem persists, please contact your local CEDES representative (www.cedes.com).
13. Maintenance
Although the TOFniva does not need regular maintenance,
a periodical functional check is strongly recommended as
follows:
Check the mounting position and detection area of the
sensor.
Clean the optical window with a soft towel and a little soapy
water.
14. Disposal
The TOFniva should only be replaced if a similar protection device is installed. Disposal should be done using the most
up-to-date recycling technology according to local regulations and laws. There are no harmful materials used in the
design and manufacture of the sensor. Traces of such dangerous materials may be found in the electronic components
but not in the quantities that are harmful.
Figure 9:
After start-up the bollards are blanked out
from the detection field.
Figure 11:
A static object is placed in the
detection field (i.e a trash bag).
The object will be detected.
Figure 12:
After 30 s the static object will
be blanked out and the TOFniva
continues its operation with the
new geometry of the detection
field.
LED dimmed
LED dimmed
LED dimmed
LED bright
LED dimmed
LED dimmed
LED bright
LED dimmed
LED dimmed
LED bright
LED dimmed
Status
Action
LED off
Check supply power
Check electrical connections
Object in the safeguarded area and LED dimmed red
Check distance setting
No object in the safeguarded area and LED bright red
Check electrical connections
Check distance setting
NOTICE
Damage to the optical window
Never use any solvents, cleaners or
mechanically abrasive towels or highpressure
water to clean the sensors.