7. Input / Output description and electrical connection
Generally the TOFniva has one output that is triggered if the detection field is interrupted. For this purpose, a push-pull
output is used. With the logic selector (gray wire, Figure 6), the logic of the output signal can be configured for “HIGH“
on object or “LOW“ on object operation (Figure 5), according to the controller requirements.
The logic selection is performed during start-up.
U
SP
0 V
Output
Logic selector connected to GND (0 V)
U
SP
0 V
Output
Logic selector connected to U
SP
Figure 5:
Output (PNP/NPN) logic
8. Start-up
1. Switch on mains and power up.
2. Check if LED lights up.
3. Check the distance setting and the reaction of the sensor, including the status LED, by placing an object into the
detection area at different heights and widths.
9. Timing diagram
Time
Value
[ms]
Power-on
time
t
1
1,000
Max. response
time
t
2
200
Release time
t
3
200
Min. switching
time
t
4
200
On
Off
Object
No object
HIGH
LOW
HIGH
LOW
t
2
t
3
t
1
t
4
Off
Dimmed
Dimmed
Bright
X
X
X
X
HIGH on object
Output
Power supply
LED status
LOW on object
Output
Object detection
Figure 7:
General timing diagram / general timing table
10. LED signals
The red LED provides the sensor's status. The respective LED is dimmed when the power is OK and the detection field
is free. The LED glows bright when an object is detected and the respective output triggered. The LED is visible from
the front.
Figure 6:
Connection diagram
LED status
Description
LED off
No power
LED dimmed red
No object detected
LED bright red
Object detected
Con
tr
oller
U
SP
GND (0 V)
n.c.
Selectable output logic
Output
n.c. = not connected and isolated
n.c.
black
brown
green
blue
white
gray
TOF/Start-EA