www.usaprocom.com
200006-01B
20
Figure 24 - Switches
SWITCHES OPERATION
Heating Coil Switch
When the switch is on
I
, the blower and heat-
ing coil turn on at the same time. It makes the
room temperature rises rapidly.
Blower Switch
When the blower and heating coil switch is
on
O
, turn the blower switch to
I
then the
blower turns on.
OFF
OFF
ON
ON
Blower
Switch
Heating
Coil Switch
Heating
Working
Light
TO TURN OFF GAS TO APPLIANCE
Shutting Off Heater
Turn control knob clockwise
to the
OFF position.
Shutting Off Burner Only (pilot
stays lit )
Turn control knob clockwise
to the
PILOT position.
MANUAL LIGHTING PROCEDURE
1. Remove front panel.
2. Follow steps 2 through 5 under
Lighting
Instructions
, page 19.
3. With control knob pressed in, strike match.
Hold match to pilot until pilot lights.
4. Keep control knob pressed in for 30 sec-
onds after lighting pilot. After 30 seconds,
release control knob. Follow step 9 under
Lighting Instructions
, page 19.
5. Replace front panel.
Figure 23 - Pilot Assembly
Pilot Air
Inlet Hole
Natural
Gas
Burner
Propane/LP
Gas Burner
Ignitor
Electrode
Thermocouple
Pilot Air Inlet Hole
OPERATION