www.usaprocom.com
17
200130-01C
Figure 18 - Equipment Shutoff Valve
CHECKING GAS CONNECTIONS
Open
Closed
Equipment
Shutoff Valve
1. Disconnect heater with its appliance main
gas valve (control valve) and equipment
shutoff valve from gas supply piping sys-
tem. Pressures in excess of 1/2 PSIG will
damage heater regulator.
2. Cap off open end of gas pipe where equip-
ment shutoff valve was connected.
3. Pressurize supply piping system by either
using compressed air or opening gas sup-
ply valve.
INSTALLATION
WARNING: Test all gas piping
and connections for leaks after
installing or servicing. Correct
all leaks at once.
WARNING: Never use an open
flame to check for a leak. Apply a
mixture of liquid soap and water
to all joints. If bubbles form, there
is a leak. Correct all leaks at once.
PRESSURE TESTING GAS SUPPLY PIPING SYSTEM
Test Pressures In Excess Of 1/2 PSIG (3.5 kPa)
4. Check all joints of gas supply piping
system. Apply mixture of liquid soap and
water to gas joints. If bubbles form, there
may be a leak.
5. Correct all leaks at once.
6. Reconnect heater and equipment shutoff
valve to gas supply. Check reconnected
fittings for leaks.
Test Pressures Equal To or Less Than 1/2 PSIG (3.5 kPa)
1.
Close equipment shutoff valve (see Figure 18).
2. Pressurize supply piping system by either
using compressed air or opening gas sup-
ply valve.
3. Check all joints from gas supply (see Fig-
ure 19 or 20) to equipment shutoff valve.
Apply a noncorrosive leak detection fluid
to all joints. Bubbles forming show a leak.
4. Correct all leaks at once.
PRESSURE TESTING HEATER GAS CONNECTIONS
to all joints. Bubbles forming show a leak.
5. Correct all leaks at once.
6. Light heater (see
Lighting Instructions
on
page 18). Check all other internal joints
for leaks.
7. Turn off heater (see
To Turn Off Gas Ap-
pliance
, page 19).
1.
Open equipment shutoff valve (see Figure 18).
2. Open gas supply tank valve.
3. Make sure control knob of heater is in the
OFF position.
4. Check all joints from equipment shutoff
valve to control valve (see Figure 19 or 20).
Apply a noncorrosive leak detection fluid
Gas Valve
Gas Valve
Equipment
Shutoff Valve
Equipment Shutoff Valve
Propane/LP
Supply Tank
Figure 19 - Checking Gas Joints for
Propane/LP Gas
Figure 20 - Checking Gas Joints for
Natural Gas
Gas Meter
Содержание MD10TBU
Страница 28: ...www usaprocom com 200130 01C 28 PARTS MODEL MD10TBU 1 3 9 4 5 2 6 7 8 ...
Страница 30: ...www usaprocom com 200130 01C 30 PARTS MODELS MD20TBU AND MD30TBU 10 1 2 4 6 7 8 5 3 9 ...
Страница 62: ...www usaprocom com 200130 01C 62 PIEZAS MODELO MD10TBU 1 3 9 4 5 2 6 7 8 ...
Страница 64: ...www usaprocom com 200130 01C 64 PIEZAS MODELOS MD20TBU Y MD30TBU 10 1 2 4 6 7 8 5 3 9 ...