background image

INFORMATION CONCERNING

ENVIRONMENTAL PROTECTION

Since the adoption of the European guidelines  2002/96/EG 
and 2006/66/EG into national law the following applies: 
Electric and electronic devices as   well as batteries may not 
be disposed of with the normal   household refuse. The 

consumer is legally required to dispose of these articles through the 
official collection points or to return them to the place of purchase. 
Local restrictions and requirements are set by local authorities. The 
symbol  found on the product, packaging or users manual indicates 
the classification of the product. By disposing of these used devices 
and batteries in a responsible manner you are playing an important 
role in our efforts to protect our environment. 

HELP

Problem

Cause

Solution

Batteries do not have

enough power.

Replace batteries.

Heating

element

does not

warm up.

Is the boiler water

temperature O.K.?

Valve does not open,

is it calcified after

the summer/heating 

pause?

Adjust the temperature 

of the boiler water. 

Remove the 

A00900001

 

move the valve

stem back and forth per 

hand or with a tool.

Heating ele-

ment

does

not cool

down.

Valve does not close

completely. 

It may be that the clos-

ing point of your valve 

seat has shifted.

Adapt again (see 

“Adapting”) Move the 

valve stem several times 

by hand, it may be that 

adaptation is impossible 

because your valve is 

calcified or the seat 

no longer performs its 

function.

Pressure
piece falls
out (This can
also cause
an E1-error) 

Due to an endessthread 

the pressure piece, 

which is situated at the 

bottom, can fall out if 

the device has not been 

affixed on the valve.

Put in the pressure 

piece. The device can 

beadapted by pressing 

the OK button or by 

removing and inserting 

the batteries. The 

endlessthread is rotating 

now and fi xes the pres-

sure piece again. Just 

install it to the radiator 

and adapt

it once again.

 - 

By pressing OK button message will be deleted in 

the display and the adapter is re-started (display 

shows PREP and afterwards INST).
No adaptation possible.  

K470W is not installed to 

the valve.

Is the installation OK?

Install 

A00900001

 to the 

heater.

Valve stroke is too

short or low batteries.

Open and close the 

valve several times 

manually or replace the 

batteries.

Motor movement is

not possible.

Does the valve stem

move freely?

For other faults and malfunctions (communication 
errors, etc...), you must remove and reinsert the 
batteries.

TECHNICAL DATA

• Power supply: 2 batteries 1,5 V type AA (stilo)
• Protection degree: IP20
• Temperature range: 0÷50 °C
• Temperature of stock: -20÷70 °C
• Communication standard: ZigBee bidirectional
• Radio frequency: 2,4 GHz
• Temperature range control: 6÷28 °C
• Dimensions (LxBxH): 88x55x65 mm
• Measuring frequency: temperature measurement every minute

Keeping  the 

A00800001

  display  off  for  long 

periods can cause an higher consumption of the 
batteries  of 

A00900001

  chronothermostat  for 

radiators.

Cedac102 srl

C.F e P.Iva 03118301203

Via del Lavoro, 47 

‐ 40033 Casalecchio di Reno (BO)

+39 

051 6139 102 

 

6

     

+39 

051 6139 102 

*

 

info

@klima102.

com

 

     

   

 

 

 

                

 

 

 

 

           

www.klima102.it

Содержание Klima102 A00900001

Страница 1: ...o adattamento Il cronotermostato A00900001 si adatterà alla corsa della valvola termostatizzabile Questa operazione può richiedere qualche minuto Finito l adattamento il A00900001 ritorna in modalità normale Se è richiesto un altro adattamento per esempio se la valvola non ha chiuso completamente durante il primo adattamento selezionare dopo aver premuto il pulsante MENU e far ripartire l operazio...

Страница 2: ...e Questo può causare anche un errore E1 Il pistoncino lavora su una vite senza fine e l eventuale utilizzo a vuoto senza valvola può portare alla sua fuoriuscita Inserire il pistoncino Attivare la funzione ADAP dal OK oppure togliere e rimettere le batterie La vite senza fine si attiverà riportando il pistoncino in posizione Ora basta installarlo sul radiatore e atti vare nuovamente la funzione ad...

Страница 3: ...tion Initial installation press the button OK until appears on the display so that A00900001 will be able to start its adaptation The device will adapt itself to the stroke of your valve body To do this the valve will now be opened and closed several times to store the end points In some cases this process can take a few minutes After successful adaptation it returns to normal mode Should adaptati...

Страница 4: ...n Pressure piece falls out This can also cause an E1 error Due to an endessthread the pressure piece which is situated at the bottom can fall out if the device has not been affixed on the valve Put in the pressure piece The device can beadapted by pressing the OK button or by removing and inserting the batteries The endlessthread is rotating now and fi xes the pres sure piece again Just install it...

Отзывы: