INFORMATION CONCERNING
ENVIRONMENTAL PROTECTION
Since the adoption of the European guidelines 2002/96/EG
and 2006/66/EG into national law the following applies:
Electric and electronic devices as well as batteries may not
be disposed of with the normal household refuse. The
consumer is legally required to dispose of these articles through the
official collection points or to return them to the place of purchase.
Local restrictions and requirements are set by local authorities. The
symbol found on the product, packaging or users manual indicates
the classification of the product. By disposing of these used devices
and batteries in a responsible manner you are playing an important
role in our efforts to protect our environment.
HELP
Problem
Cause
Solution
Batteries do not have
enough power.
Replace batteries.
Heating
element
does not
warm up.
Is the boiler water
temperature O.K.?
Valve does not open,
is it calcified after
the summer/heating
pause?
Adjust the temperature
of the boiler water.
Remove the
A00900001
move the valve
stem back and forth per
hand or with a tool.
Heating ele-
ment
does
not cool
down.
Valve does not close
completely.
It may be that the clos-
ing point of your valve
seat has shifted.
Adapt again (see
“Adapting”) Move the
valve stem several times
by hand, it may be that
adaptation is impossible
because your valve is
calcified or the seat
no longer performs its
function.
Pressure
piece falls
out (This can
also cause
an E1-error)
Due to an endessthread
the pressure piece,
which is situated at the
bottom, can fall out if
the device has not been
affixed on the valve.
Put in the pressure
piece. The device can
beadapted by pressing
the OK button or by
removing and inserting
the batteries. The
endlessthread is rotating
now and fi xes the pres-
sure piece again. Just
install it to the radiator
and adapt
it once again.
-
By pressing OK button message will be deleted in
the display and the adapter is re-started (display
shows PREP and afterwards INST).
No adaptation possible.
K470W is not installed to
the valve.
Is the installation OK?
Install
A00900001
to the
heater.
Valve stroke is too
short or low batteries.
Open and close the
valve several times
manually or replace the
batteries.
Motor movement is
not possible.
Does the valve stem
move freely?
For other faults and malfunctions (communication
errors, etc...), you must remove and reinsert the
batteries.
TECHNICAL DATA
• Power supply: 2 batteries 1,5 V type AA (stilo)
• Protection degree: IP20
• Temperature range: 0÷50 °C
• Temperature of stock: -20÷70 °C
• Communication standard: ZigBee bidirectional
• Radio frequency: 2,4 GHz
• Temperature range control: 6÷28 °C
• Dimensions (LxBxH): 88x55x65 mm
• Measuring frequency: temperature measurement every minute
Keeping the
A00800001
display off for long
periods can cause an higher consumption of the
batteries of
A00900001
chronothermostat for
radiators.
Cedac102 srl
C.F e P.Iva 03118301203
Via del Lavoro, 47
‐ 40033 Casalecchio di Reno (BO)
'
+39
051 6139 102
6
+39
051 6139 102
*
info
@klima102.
com
www.klima102.it