background image

WIRELESS 

CHRONOTHERMOSTAT 

FOR RADIATORS

 

A00900001

“STANDARD 

HA1.2 ZIGBEE”

Read these instructions carefully before installing the device, and keep 
them for future consultation.  

The pack contains: n.1 chronothermostat 

A00900001

 with fixing ring 

nut  M30x1,5  mm,  n.1  sachet  containing  an  adaptor  for  the  ring  nut 
M30x1,5 mm; n.1 installation and user manual.

Application as directed

By purchasing the 

A00900001

 wireless chronothermostat you 

own a programmable radiator thermostat which can be used for 
temperature regulations in enclosed rooms and therefore, it can 
contribute to the reduction of heating energy.
Please use the thermostat only for this purpose.

Display and control elements

 Child lock active 

2

 

 Battery  low 

3.a    

Window/freeze protection function
active

3.b 

Wireless active 

AUTO or MANU mode active

5.a  

Button 

MENU

 – leads to the main 

menu (starting from regular display); 
within the menu one keypress leads 
to the previous level

5.b  

Button 

OK

 – confirmation of 

setting

5.c 

Button

– timer function

Selector wheel

Setup menu

By pressing 

MENU

 you will arrive at the set up menu. Please choose 

one of the items with the selector wheel.
With 

OK

 you can select one menu item and with the selection 

wheel they can be adjusted. The button 

OK

 confirms the setting. 

The button 

MENU

 leads to the previous level.

PAIR  

JOIN =  addition process  
DEL = deletion process

ADAP 

Starting of a new valve adjustment 

INST  

Installation function (Please only attach The controller 
to the coupling ring when INST shows on screen)

RES  

Reset of the device to factory default.
The radio connection will continue to exist.

STBY   

Turns the LCD on or off to save battery power 

VERS   

Shows current firmware version

Before installing the batteries, proceed by installing 

the correct adapters on the valve body.

Inserting / replacing batteries

Remove the battery lid by pressing the battery lid upwards (1) at the 
highlighted point and then taking it out (2).

(2)

(1)

Never recharge batteries, danger of explosion! Do not short circuit bat-
teries! Take low batteries out of the device immediately.
Keep batteries away from extreme warming – danger of leakage!
Do not apply used and new batteries together.
If needed, clean the battery and the contacts before using them.
Keep the batteries away from children. Avoid contact with the eyes 
and mucous membranes. When getting in touch with battery acid 
instantly irrigate the affected partswith clear water and call a doctor.

Preparation for installation

On the display  will be shown. Now, the motor will completely 
move to the installation position in order to make the installation 
easier. As soon as 

A00900001

 is ready for installation  will be shown 

on the display (

 

- any time selected in the menu).

Now please do not press any other buttons!
Plug device for coupling ring.

Installation on 

klima102

 valves with thermostatic option, 

with connection M30x1,5 mm

The chronothermostat is installed on all the 

klima102

 valves with 

thermostatic option of the H series, with connection M30x1,5 mm, as 
shown below:
• Tighten the ring nut (B) of the chronothermostat on the radiator valve (A).

B

A

Installation on other 

klima102

 valves with thermostatic option

 

When  installing  on 

klima102

  valves  with  thermostatic  option,  use  the 

contents of the sachet  (included in the chronothermostat package).

• Fit the threaded ring nut (C), coupling it with the reference pins (P) on 
the radiator valve (D).

C

D

P

• Tighten the ring nut (B) of the chronothermostat on the radiator valve 
(C+D).

B

C+D

The chronothermostat must be in “INST” or “ON” mode in order to fix it 
to the ring nut without too much effort.
If the chronothermostat is installed at a later time, select the “INST” 
menu before fixing it to the ring nut.
To ensure better temperature adjustment, you are advised to install the 
chronothermostat with the display facing upwards.

Adaptation

Initial installation: press the button 

OK

 until 

 appears on the 

display so that 

A00900001

 will be able to start its adaptation.

The device will adapt itself to the stroke of your valve body.
To do this the valve will now be opened and closed several times to 
store the end points. In some cases this process can take a few minutes. 
After successful adaptation it returns to normal mode. 
• Should adaptation become necessary again, e.g. if your radiator does 
not cool down in the position, please press in the menu the button 

 until adaptation starts again.

Addition/removal to/from the network

In order to enrol and delete the device manually, start the enrolment/ 
deletion process of your display 

A00800001

.

Now select the menu PAIR at the thermostat and confirm with 

OK

     

Now select the menu item JOIN and confirm with 

OK

      

.

Within 90 sec. the device has successfully joined the network if the 
wireless icon   lights up permanently.
To remove the device from a network, select the menu PAIR, then select 
the submenu DEL by using the selector wheel and confirm with 

OK

      

T

he device performs the delete operation and will be removed from the 

network (within 90 sec.).

After the connection and the appearance of the 
symbol  , if you accidentally press OK again to 
JOIN,  the  valve  leave  the  associate  Display 

A00800001

 to search another Display 

A00800001

 

no longer what it was associated.

You should use the DEL before trying a second time the JOIN on 
the same Display 

A00800001

.

Removing the chronotermostat

Set the maximum temperature via the wheel selector (the display will 
show “ON”) and wait at least one minute. Unscrew the ring nut (B) of 
the chronothermostat from the radiator valve.

B

BASIC OPERATING MODES

With the selector wheel is possible to change the ambient temperature 
in every moments.

FURTHER FUNCTIONS

Timer function

The timer function is selected with the timer-button .
With this function a user-defined temperature for a programmable 
period can be entered.
This can be very useful in case of a party, for example.
Press  first, the time for which the time programme has been 
deactivated is shown. Confirm with 

O K

 

.

Now, the desired temperature can be set. Confirm with 

O K

 

.

In the selected period it is not possible to change the temperature 
manual, the wheel is locked. Press Menu to unlock it.

Window function

If you open a window and consequently the temperature drops 
significantly, the 

A00900001

 will automatically close the heating valve 

in order to save energy. The display will show .
Afterwards, the 

A00900001

 will resume normal operation.

Vacation function

The vacation mode can be set only by the 

A00800001

 display or 

the dedicated APP. Activating the holiday mode ALL the 

A00900001

 

connected to the network go OFF. The holiday mode is always and only 
deactivated by the 

A00800001

 display or the dedicated APP.

Child lock

You can lock the 

A00900001 

to protect the device from 

unauthorized activation. Press the buttons 

OK

 +  at the same 

time for about 2 seconds until the signal  appears on the display in 
order to lock the device. By using this button combination again the 
symbol disappears and you release the lock.

Display in standby  

The display goes in standby mode automatically after 30 sec.
To reactive it, press any buttons or the selector wheel.

Going back to factory preset/All reset

Press 

MENU

. Select the menu item 

 with the selector wheel.

Confirm with 

OK

 

.   flashes, confirm with 

OK

 

.

A00900001

 is reset again. Now, proceed as described for the initial

 

operation. The unit is still connected to the network.

Freeze protection and calcification protection 

f

unction are 

active automatically:

Freeze protection function

If the temperature drops below 6°C, the 

A00900001

 opens the valve until 

the temperature again rises above 8°C.

 

This prevents the radiators from 

freezing.

Calcification protection function

To prevent radiator valves from calcifying, the 

A00900001

 is submitted to 

a calcification protection programme once a week on Friday mornings.

Mo

Di

Mi

Do

Fr

Sa

So

:

AUTO

MANU

MENU

OK

3

1
2

4

6

5

Содержание Klima102 A00900001

Страница 1: ...o adattamento Il cronotermostato A00900001 si adatterà alla corsa della valvola termostatizzabile Questa operazione può richiedere qualche minuto Finito l adattamento il A00900001 ritorna in modalità normale Se è richiesto un altro adattamento per esempio se la valvola non ha chiuso completamente durante il primo adattamento selezionare dopo aver premuto il pulsante MENU e far ripartire l operazio...

Страница 2: ...e Questo può causare anche un errore E1 Il pistoncino lavora su una vite senza fine e l eventuale utilizzo a vuoto senza valvola può portare alla sua fuoriuscita Inserire il pistoncino Attivare la funzione ADAP dal OK oppure togliere e rimettere le batterie La vite senza fine si attiverà riportando il pistoncino in posizione Ora basta installarlo sul radiatore e atti vare nuovamente la funzione ad...

Страница 3: ...tion Initial installation press the button OK until appears on the display so that A00900001 will be able to start its adaptation The device will adapt itself to the stroke of your valve body To do this the valve will now be opened and closed several times to store the end points In some cases this process can take a few minutes After successful adaptation it returns to normal mode Should adaptati...

Страница 4: ...n Pressure piece falls out This can also cause an E1 error Due to an endessthread the pressure piece which is situated at the bottom can fall out if the device has not been affixed on the valve Put in the pressure piece The device can beadapted by pressing the OK button or by removing and inserting the batteries The endlessthread is rotating now and fi xes the pres sure piece again Just install it...

Отзывы: