12.
MULTI- PAR TIME SELECTION:
(Continued….)
(The above example shows three Par times being activated by a single start beep. A total of four beeps
will be emitted from the timer. One START beep and three PAR beeps at the intervals selected. Each
PAR time entered will be based from the previous one. Therefore in the above example, from the timer
activation (start beep), the next beep will begin at 1.0 second, followed by another beep starting at 2.25
seconds, with the final beep starting at 3.45 seconds.)
To activate the timer and the selected “Par times”, simply press the START button. A second “stop”
beep will occur at EACH of the selected “Par times”. The timer will continue to record shots through-
out the entire process, even after the selected Par times have elapsed. This allows accurate review of
all shots and their exact times fired. This selected programming will remain active until cleared. This
allows the user to practice a given selected drill over and over again.
PLEASE NOTE:
When using Multi-Par, the timer display will indicate the multiple Par 1 value as
the PAR time on the display and show the mode (MULTI-PAR1) in the lower display matrix area.
Once the timer is activated and as each Multi-Par setting progress, the current value will appear on the
display in an ongoing progression.
(When in a PAR time function, ALL (Par) beeps will sound at the exact pre-set time for a 0.30 sec-
ond duration! Note, that when in Multi-Par, a maximum Par time of 99.99 seconds is allowed)
To clear an existing Par setting, select the Menu, and then scroll down to CLEAR MODE and press
ENTER. This will clear any PAR settings, functions, or mode in current use and return the timer to
Comstock ready mode
R.O. (RANGE OFFICER) MODE:
Designed for Range Officers who want to use a timer for match or instructor purposes and desire only
basic operation without additional features. When selected, the timer Menu only shows the follow-
ing basic functions. DELAY, SINGLE PAR, & SENSITIVITY. The user can select the delay option
desired and adjust sensitivity and set a single Par time. The timer will then allow START & REVIEW
functions and the display continues to show all information as normal. ALL OTHER FEATURES
AND FUNCTIONS OF THIS TIIMER ARE HIDDEN AND INACTIVE WHEN IN RO MODE. To
activate : Select Menu, and scroll down to highlight RO Mode – press ENTER – Highlight either ON
or OFF and press ENTER.