10.
PROGRAMMABLE PAR TIME SELECTION:
A single PAR time can be set allowing the user to create a fixed interval of time. Selection of a “Par
time” from 0.60 to 999.99 seconds can be accomplished with the CED7000. (Note: Par time can be
set to the 1/100th sec level) Since the START buzzer duration beeps for 0.50 seconds, the minimum
PAR time accepted by the timer is 0.60 seconds. To select a PAR time, press MENU. Scroll down
to select the “PAR” mode, highlight it, and press ENTER to confirm it. Select Par (for a single Par
setting), Custom Par (for up to 11 Par times to be activated one after the next each timer the START is
pressed), Auto Par (for up to 11 Par times and 11 delay times to be run automatically from one activa-
tion), or Multiple Par (to run up to 5 Par times from one single activation) and press ENTER again.
Press the “right” key to highlight the first column and then scroll up or down to select a value from 0
to 9 and then press the “right” key to highlight the second column and select a value for it and so on
until all five value columns are set. Once the desired Par time is displayed, then confirm the time set
by pressing ENTER.
To activate the timer and the selected “Par time”, simply press the START button. A second “stop”
beep will occur at the selected “Par time”. The timer will continue to record shots even after the se-
lected Par time has elapsed. This allows accurate review of all late shots and their exact time fired.
When in PAR time mode, the second beep will sound at the exact pre-set time for a 0.30 second
duration.
(Example – If a 5.00 second PAR time is selected, the PAR time is counted from the instant the
buzzer begins sounding (zero time) with the final 0.30 second beep sounding precisely at 5.00
seconds, ending at 5.30 seconds total time)
The CED7000 timer also features the ability to be programmed with up to eleven multiple PAR times
as well as multiple delay intervals. Additionally, each PAR time and delay interval can be set to differ-
ent time lengths. When programming strings in Custom or Automatic Par, the user can clear values for
any string shown on the display by pressing the CLEAR button once. If the CLEAR button is pressed
twice, it will erase all values set for the Par selection.
When in “Custom Par”, only the Par times are set for the number of desired strings up to a maximum
of eleven. The user then activates the timer by pressing the START button, which in turn runs each
selected Par string individually. The user must re-press the START button to activate the next string,
but the timer moves forward to the next programmed Par each time it is activated until it completes all
strings programmed.
In AUTOMATIC setting, both PAR and DELAY times are selected for a number of strings up to a
maximum of eleven. Once the START button is pressed and the timer activated, it will run ALL strings
programmed automatically until completed.
Example:
String 1 PAR
3.00 sec.
Delay
2.00 sec.
String 2 PAR
5.00 sec.
Delay
3.00 sec.
String 3 PAR
6.50 sec.