Humidifier produces
an unusual smell
Humidifier is new.
Take out water tank, open cover, let
it stay 12 hours in cool position.
Dirty water or water sitting
too long.
Clean water tank, fill with clear
water.
Residual smell from diffusing
aroma oil on the aroma
cotton.
Remove the aroma cotton, rinse it
under clean water and allow it to
dry.
Humidifier makes
a loud or unusual
sound
Resonant in water tank when
water is too low.
Fill water into water tank.
Humidifier is on an unstable
surface.
Move the humidifier to a stable flat
surface.
Water tank is positioned
incorrectly.
Turn off and unplug the humidifier,
then align the water tank cover with
its respective opening in the inner
chamber.
Humidifier is malfunctioning.
Stop using the device immediately
and contact the Technical Support
Service of Cecotec.
The humidification
capacity is too low
There is natural or artificial
air replacement in the room
which interfere the increase
of %RH.
Check if doors and windows are
closed.
Check if there is no air conditioning
working in the room.
The air inlet grids and nozzle
could be blocked.
Remove any blocking items from
the grids and the nozzle.
Too much scale in the water
basin.
Clean transducer.
The humidity selected rate is
too low.
Increase mist output speed.
Increase humidity setting rate.
Water is too dirty or water
kept too long in the tank.
Clean water tank, change to fresh
clear water.
The ambient
humidity is too high
Humidifier is working in
Continuous mode.
Change the mode.
The humidity target is too
high.
Select a lower %RH target.
Room is not well-ventilated
Open a window to ensure proper
air flow for the humidifier or move
the humidifier to a better ventilated
room.
Excess water tank has
spilled while filling the water
tank or replacing the water
tank back onto the base.
Wipe off excess water from the
top and bottom of the base before
replacing the water tank.
There is
condensation in the
room
The room temperature is
too low.
Heat the room up.
The mist suddenly
stops coming out
Programmed timer period
has run out.
Turn humidifier on.
The water shortage indicator
is on.
Refill water tank.
The target humidity level is
reached.
Incorrect humidity
level is being
displayed.
Room is larger than the
effective range of the
humidifier.
Move the humidifier to a room
which is with suitable room size.
Moisture has built up inside
of the humidity sensor.
Turn off the humidifier and allow
the humidity sensor to completely
air dry before resuming use.
The nozzle is facing the
direction of the humidity
sensor.
Turn the nozzle so that it is facing
away from the humidity sensor.
Humidity sensor is broken of
defective.
Stop using the device immediately
and contact the Technical Support
Service of Cecotec.