INSTALLATION.
This equipment must be used solely for welding operations.
The equipment must be installed by qualified personnel.
All connections must be carried out in compliance with current standards and in full observance of
current safety laws.
3.1
Placement.
The combined weight of the Power Source and Cooling Unit is approximately 100 Kg, thus when lifting
following the instructions shown in fig. 2.
Position the Power Source in an area that ensures good stability, and efficient ventilation so as to prevent
metal dust from entering.
fig. 2
3.2
Power Source installation (fig. 1).
Place the Robot Interface (25) inside the Robot Control Cabinet (5), following the instructions provided
in the Robot Interface Instruction Manual.
Connect the Power Source (21) to the Control Panel (24) using the connection cable (1).
Connect the Power Source (21) to the Robot Interface (25) using the signal cable (3) and the CANopen
cable (4) (the latter is included in the Robot Interface).
Connect the Power Source (21) to the Wire Feeder (8) by means of the extension (2).
NOTE: avoid coiling the connection to reduce to a minimum the inductive effects that could affect the
results in pulsed MIG/MAG welding.
Mount the plug on the power cord, being especially carefully to connect the yellow/green conductor to the
earth pole.
Make sure that the supply voltage corresponds to the rated voltage of the Power Source.
Size the protective fuses based on the data listed on the technical specifications plate of the Power Source.
Complete the remaining connections of the other welding system equipment, consulting the relevant
Instruction Manuals in par. “Installation”.
Power up the Welding System using the switch
BU
of the Power Source (fig. 3).
NOTE: The Cooling Unit is preset by the factory to OFF. Change this setting if a water-cooled torch is
used (see par. 6.4).
3.3
Setting up the cooling unit (fig 3).
Unscrew the cap
BW
and fill the 5-liter tank. The device is supplied by the factory with approximately
one litre of fluid already present.
It is important to periodically check, through the slot
BX
, that the fluid remains at the “max” level.
As a coolant, use water (preferably de-ionized) mixed with alcohol, in the percentage shown in the
following table:
Содержание MIG 5040/T
Страница 35: ...CEBORA S p A 35 3 300 160 F 10 03 2016 Art 287 80 ...
Страница 37: ...CEBORA S p A 37 3 300 160 F 10 03 2016 Art 289 80 ...
Страница 39: ...CEBORA S p A 39 3 300 160 F 10 03 2016 ...
Страница 40: ...CEBORA S p A 40 3 300 160 F 10 03 2016 GR 52 ...
Страница 42: ...CEBORA S p A 42 3 300 160 F 10 03 2016 ...
Страница 43: ...CEBORA S p A 43 3 300 160 F 10 03 2016 ...
Страница 44: ...CEBORA S p A 44 3 300 160 F 10 03 2016 ...