SEQUENTIAL COMMAND

I-55

CHARACTERISTICS

Voltage ................................................................... 12 V. D.C.

Minimum Consumption ...........................................50 mA.

Maximum Consumption ......................................... 60 mA.

External Clock - input maxi. Frequency ................. 25 Hz.

Internal Clock - Mini. Connection time by relay ..... 0,3 Sec.

Internal Clock - Maxi. Connection time by relay .... 10 Sec.

Maximum Output Load By Relay ........................... 5 A.

Protection Against Polarity Inversion ..................... Yes

Sizes ...................................................................... 155 x 102 x 30 mm.

The I-55 module is a sequential command with 8 relay outputs. With each impulse, relays will be connected one after one, and 

disconnecting the previous one.

The sequence could be produce by external impulses or thanks to an internal oscillator.

The oscillator is adjusted with a potentiometer inserted in the PCB. It includes reset output, protection against polarity inversion, indicator 

output led and terminals to connect it.

Do not forget to read all the information sheet in order to obtain a perfect operating of the module.

POWER SUPPLY.

 

The I-203 circuit had to be supplied by a 12 VDC power supply.

Then, we recommended you the FE-2 power supply which has been developed to perfectly answer to the circuit needs or a 12 V batteries 

for mobile applications. Install a fuse and a switch as it is indicated in the drawing. Both are obligatory to guarantee a correct protection of 

the module as well as for your own safety as it is required by the "CE" marking.

Connect the positive of the power supply to the positive terminal indicated in the wiring map, then connect also the negative of the power 
supply to the negative terminal indicated in the circuit. 

Verify

 that the assembly has been correctly done.

OPERATING.

 See the general wiring map. The module has a switch indicated as INT-1. Thanks to this switch you could select between 

automatic operating (controlled by the internal oscillator) and manual operating which be externally inserted. 

Regarding manual operating.

 you have to place (in the switch INT-1) the contact Nº1 in ON position and the contact Nº2 in OFF 

position. Do not place permanently both contact in the same position to avoid to damage the module. See the drawing.

Connect a push button to the terminal indicated as impulses input (See General wiring map). If you have to connect a clock signal from an 

other apparatus, you have to respect their polarity and verify that it is a 12 VDC signal. When the push button is installed, after each 

pressure relay will be activated one after one, and disconnecting the previous one.

Regarding automatic operating

. you have to place (in the switch INT-1) the contact Nº1 in OFF position and the contact Nº2 in ON 

position. Do not place permanently both contact in the same position to avoid to damage the module. See the drawing.

Adjust the speed using the potentiometer inserted in the PCB to adjust the frequency. After each pressure relay will be activated one after 

one, and disconnecting the previous one.

OPERATING

REST.

 See the general wiring map. Connect a push button to the terminal indicated as "Reset". Each time you press this push button 

and independently of the activated relay, the module will come back at the beginning of the sequence (to the first relay) until you stop to 

press the "reset" push button.