background image

IF324_5A808_UK_M1                          

                                                                                                 

® Copyright CEAM Group 

 

 

 

 

 

CEAM Control Equipment                                                           

13

5.3.3 – Re-Reading Stored Data in LOG - Measure IF (Infrared) 

To read again these data proceed as follows:      
 
Keeping pressed the measurement trigger (Ref. Chap.3 – Pos.9), press repeatedly the key  

MODE

 until on the  

display it appears the abbreviation 

LOG

 (Ref. Chap.4 – Pos. 14), at this point release the trigger, and operating 

on the keys 

UP

 & 

DOWN

, it is possible to scroll the several memory positions, visualizing them from  1 to 100 

on  the  display  in  little  on  the  high  side  (Ref.Chap.4  –  Pos.8)  ,  the  stored  temperature  corresponding  to  the 
memory cell is visualized on the display in little on the low side (Ref. Chap.4 – Pos.9)        
 

Note: Not touching anymore any key for at least 7 seconds the instrument switch itself off 

 

5.3.4 – Erasing of the LOG Storage  

This  function  allows  to  erase  quickly  all  the  stored  data  in  the  LOG,  and  to  proceed  execute  the  following 
procedure:  
 
The erasing can be made only when the instrument is in 

LOG

, this state is confirmed by the visualization of the 

abbreviation  on  the  (Ref.  Chap.  4  –  Pos.  14),  if  the  display  does  not  visualize  this  abbreviation,  always  in 

MEASURE

,  with  pressed  trigger,  press  repeatedly  the  key 

MODE

  (Ref.Chap.5  –  Pos.4)  until  it  appears  the 

abbreviation LOG.  
 
Once  assured  to  be  in 

LOG

,  always  keeping  pressed  the  trigger,  pressing  repeatedly  the  key 

DOWN

  up  to 

arriving in visualizing the memory cell 

0

, visualized on the display little in the high side (Ref.Chap. 4 – Pos.8), 

without  releasing  the  trigger,  press  shortly  the  red  key  Backlighting/Laser  (Ref.  Chap.5  –  Pos.1),  the 
instrument will confirm the erasing with a double sound note, and the display will visualize the memory cell 

1

ready to begin a new storage     
 

5.3.5 – Activation –Deactivation USB Gate to download data  

The instrument is supplied by a digital communication USB gate, through which it is possible to download the 
stored data to visualize them on the PC.  
 
Activation USB  Gate: To activate it, it is necessary that the instrument is in the state 

MAX

-

MIN

-

DIF

-

AVG

, with 

one of these abbreviations visualized on the display (Ref. Chap.4 – Pos.7), then keep pressed for few seconds 
the red key Backlighting-Laser (Ref. Chap.5 – Pos.1) until the abbreviation 

USB

 appears in the low right corner 

of the display (Ref. Chap.4 – Pos.11).  
 
Deactivation USB gate: To deactivate the function, it is necessary  that the instrument is in the state 

MAX

-

MIN

-

DIF

-

AVG

, with one of these abbreviations visualized on the display (Ref. Chap.4 – Pos.7), then keep pressed for 

few seconds the red key Backlighting-Laser (Ref. Chap.5 – Pos.1) until the abbreviation 

USB

 disappears from 

the low right corner of the display (Ref. Chap.4 – Pos.11).  
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Содержание IF324

Страница 1: ... measurement No contact with Thermocouple Type K IR Range 50 0 1600 0 C Range T C Tipo K 50 0 1370 C With a double Laser Pointer USB Gate Software Ms Windows Art 5A808 Operating Manual Cod IF324_5A808_UK_M1 English Language Product Rev 1 0 Manual Rev 1 2 ...

Страница 2: ...IF324_5A808_UK_M1 Copyright CEAM Group CEAM Control Equipment 2 ...

Страница 3: ...rd 5 1 Instrument General Functions 5 2 MODE Key Functionality 5 3 LOG Functionality Data Logger 6 Measurement Procedure 6 1 Instrument Switching On 6 2 Warning SCAN Measurement Activated 6 3 Warning HOLD Measurement NOT Activated 6 4 Automatic Switching Off Function Power Saving 6 5 Important Consideration about the Measures 7 Battery Changing 7 1 Indication Low Battery 7 2 Battery place Opening ...

Страница 4: ...IF324_5A808_UK_M1 Copyright CEAM Group CEAM Control Equipment 4 ...

Страница 5: ...IF324_5A808_UK_M1 Copyright CEAM Group CEAM Control Equipment 5 ...

Страница 6: ...m the Spot will have a diameter of 100 mm Fig 1 and at the distance of 12 meters the spot will have a diameter of 1 meter of course this ratio is true also for intermeddle or superior measures to the mentioned values Laser Pointer The Laser ray is used only to simplify the measurement pointing allowing identifying with precision the exact point where the operator is making the measurement and it i...

Страница 7: ...surfaces which could the ray in an uncontrolled way Never point the Laser ray on gas or inflammable and or explosive liquids You should never exceed the operative limits written on this manual reminding also that a respectable using extend the product s life The product is not hermetic and it cannot stand humidity steams and liquids which could damage both the electronic and the optical side Avoid...

Страница 8: ... of the Trigger Energy save Function with Automatic Power OFF Operative Conditions 0 50 C 32 122 F 10 90 UR Stocking Conditions 10 60 C 14 140 F 5 80 UR Power Supply Battery 9V NEDA 1604A IEC 6RL61 or Equivalent Characteristics Measures without Contact Infrared Infrared Measure Range 50 1600 C 58 0 2912 F Optical Ratio 50 1 to the Distance of 50 cm it has a Spot Diameter 1 cm Accuracy Look at Tabl...

Страница 9: ...vided by a micro processor able to make complex calculations it converts the radiations in a precise temperature measure Then as it should be clear the instrument act itself as an optical Passive device with a result that the major will be the distance between the instrument and the Target Target Point of Measure and major will be the dimension of the SPOT and vice versa as explained in the below ...

Страница 10: ...tact with infrared Table Range Precision for the Measurements without Contact with Infrared Range C Range F Precision Repeatability Display Resolution 50 20 58 68 2 5 C 4 5 F 1 3 C 2 3 F 0 1 1000 1 1000 20 400 68 752 1 0 1 0 C 1 8 F 0 8 0 5 C 0 9 F 400 800 752 1472 1 5 2 0 C 3 6 F 800 1200 1472 2912 2 5 1200 1600 1472 2912 2 5 1 2 1 0 C 1 8 F Rif Conditions Environmental Temp 23 25 C 73 77 F 3 Ins...

Страница 11: ... this period the instrument visualize on the display the word SCAN Ref Cap 4 Pos 1 for short this period would be denominated MEASURE HOLD This mode activates itself automatically when you release the trigger Ref Chap 3 Pos 9 after the measurement and if you don t press any key during this time and you did not disable the energy save function the instrument automatically turns off after few second...

Страница 12: ...UP DOWN Ref Chap 5 Pos 2 3 Continuing And to the configuration of the parameters in sequence ε EMS Emissivity Set for the infrared measurement LOCK On Off Activation Deactivation Keyboard Lock H HAL On Off Activation Deactivation High temperature Sound Alarm H HAL Set Point Value Set Set Point High temperature Alarm L LAL On Off Activation Deactivation Low temperature Sound Alarm L LAL Set Point S...

Страница 13: ...appears the abbreviation LOG Once assured to be in LOG always keeping pressed the trigger pressing repeatedly the key DOWN up to arriving in visualizing the memory cell 0 visualized on the display little in the high side Ref Chap 4 Pos 8 without releasing the trigger press shortly the red key Backlighting Laser Ref Chap 5 Pos 1 the instrument will confirm the erasing with a double sound note and t...

Страница 14: ...with a different temperature and outside the body to be measured the result would be in proportion distorted B the measurement infrared sensor needs the environmental temperature compensation which the instrument makes automatically but to obtain reliable measurements it is necessary to allow to the instrument to adapt itself thermally to the environment where it is especially if before it was in ...

Страница 15: ...l while if we are measuring irregular bodies the shape of the SPOT will assume irregular shapes as consequence IDEA To have an idea of how it works it is enough to use an electric torch which produces a light cone which besides its dimension Optical Ratio if you position it in a vertical way it will produce a round lighted area besides if you position it in a slanting way the shape of the lighted ...

Страница 16: ... specific for the various kinds of materials to be measured Here following it is published a summary table of Emissivity of the most common materials ATTENTION In case you desire to measure with more accuracy all the materials but in particular the most difficult ones or even impossible ones to be measured you can do it with a simple trick in practice it is enough to create some point of measure T...

Страница 17: ...battery or the thermocouple probes which are subject to wear Besides also for the side of measure T C but in particular for the side of the IF we suggest to verify the correct calibration at least twice a year using a calibration oven Black Body Grey Body as the ones at disposal among the optional Ref Series C400 C600 a major frequency of verifying it is suggestible in case the level of critical s...

Страница 18: ...he software and then connect the thermometer to the USB gate activating before its gate Ref Par 5 3 5 and then follow the eventual request of the system At the end once you install it correctly pressing the Trigger of the thermometer it will be possible to see on the PC the data taken by the thermometer both those with technology IF and those taken by the thermocouples if connected If everything h...

Страница 19: ...Digital Thermometer Range 50 380 C Art 5A805 IF322 Handy Infrared Thermometer 50 550 C Art 5A806 IF323 Handy infrared Thermometer 50 1600 C Art 5A807 IF301D Multi purpose Infrared Thermometer Thermocouple Input Range 0 650 IR 0 1700 C T C Accessory Rechargeable NiMh Battery Size 6LR61 Art 0942 Universal Net Battery Charger 230 Vac 50 Hz Art 0943 C430 A Calibration Kiln Black Body Range 50 350 C C4...

Страница 20: ...oes not give any right to resolute the contract or to suspend the payment if not expressly agreed in written by CEAM The warranty does not cover Defects generated by incorrect or improper use of the product Defects generated by using spare parts or consumables products not original CEAM Defects generated by environmental and or atmospheric problems and or natural calamity Products and or services ...

Страница 21: ...IF324_5A808_UK_M1 Copyright CEAM Group CEAM Control Equipment 21 ...

Страница 22: ...IF324_5A808_UK_M1 Copyright CEAM Group CEAM Control Equipment 22 ...

Страница 23: ...IF324_5A808_UK_M1 Copyright CEAM Group CEAM Control Equipment 23 ...

Страница 24: ...ia Val D Orme No 291 50053 Empoli Firenze Italy Tel 39 0571 924082 Fax 39 0571 924505 Skype Name ceam_info Internet Group Web www ceamgroup com Division Web www ceamcontrolequipment it Support Web www ceamsupport it Service E mail General info ceamgroup it Customer Service sales ceamgroup it Local Reseller ...

Отзывы: