CDVI ATRIUM ADH10 Скачать руководство пользователя страница 21

21

cdvigroup.com

EN

ADH10

ATRIUM - Schlage Integration Module (Control up to 10 Schlage Door Handles)

  INSTALLATION MANUAL

EN

ADH10

ATRIUM - Schlage Integration Module (Control up to 10 Schlage Door Handles)

  INSTALLATION MANUAL

System overview

One ATRIUM ADH10 controller has the capacity to control ten AD300 and/or AD400 SCHLAGE door handles. 

ATRIUM ver. 3.1 (or higher) multi-account software supports up to 100 door handles per account (site). For 

increased flexibility, the system also supports proximity or magnetic stripe card readers. Combine AD300/400 

door handles and card readers on the same system as shown in the diagram below.

AD-300

Wired Lock

RS485

RS485

LAN/WAN

(TCP/IP)

AD-400

Wireless Lock

NDE

Wireless Lock

PIM400-485

Panel Interface Module

GWE

Gateway

Each 

PIM400-485 or GWE can 

manage up to ten locks

.

ADH10 can manage up to ten 

PIM400-485 and/or GWE.

(ADH10 firmware version 3.3 or higher)

900MHz

Bluetooth

Low 

Energy

ADH10

Door Handle Controller

(Can manage up to ten door handle locks)

Proximity

Card Reader 

Proximity

Card Reader 

A22

Web-Based IP 2-Door Hybrid Controller

Can manage up to ten card readers

(A22 set as a controller)

A22

Set as Expander

A22

Set as Expander

A22

Set as Expander

A22

Set as Expander

Range up to 200’ 

in typical building 

construction

Range up to 100’ 

in typical building 

construction

Tablets

Smartphone

WiFi

Supports any combination of ten

A22 and/or ADH10 controllers

for a maximum of 100

card readers or door handles per site.

Содержание ATRIUM ADH10

Страница 1: ...The Installer s Choice cdvigroup com ENGLISH EN ADH10 ATRIUM Schlage Integration Module...

Страница 2: ...ches 16 Power Connections 17 AC Source 17 AC Terminal Fuse 18 Battery Backup 19 LED Indicators 20 System overview 21 6 WARRANTY TERMS CONDITIONS 22 Thank You for buying our products and for the confid...

Страница 3: ...cluded with every ADH10 making this unit an industry leader in efficiency and simplicity Control 10 door handles On board Ethernet Port with AES 256 bit encryption Auto detect technology 10 000 users...

Страница 4: ...s INSTALLATION MANUAL 2 NOTES AND RECOMMENDATIONS Free Technical Support For technical support in U S or Canada call 1 866 610 0102 Monday to Friday from 8 00 a m to 8 00 p m EST For international tec...

Страница 5: ...inium or Copper Clad Aluminium Do not use any switch controlled outlets to power the system System Resources Doors 10 doors Cards and users 10 000 cards and users Schedules 1000 Schedules each support...

Страница 6: ...IN Do Not Connect to a Receptacle Controlled by a Switch On Board Protection Fuseless auto resume Battery Against reversal short current limited monitored Power output specifications Battery Backup Ba...

Страница 7: ...tal cabinet and connection diagram label AC power cord Metal cabinet accessory kit Installation kit Wall Switch and a white wire 115mm with a log at each end Bolts and Nuts Wall Switch Spacer Door Swi...

Страница 8: ...oltage Capacity Length Width Height YUASA NP7 12 12 Volt 7 Ah 151mm 5 94 65mm 2 56 97 5mm 3 84 YUASA NP4 12 12 Volt 4 5 Ah 90mm 3 54 70mm 2 76 106mm 4 17 Multiple Conduit Knock outs Two 19 05mm 0 75 o...

Страница 9: ...TIONS The box needs to be prepared before fixing it to its location INSTALLING THE TAMPER SWITCHES Installing tamper switches allows the ADH10 to detect when the cabinet door is opened and or when the...

Страница 10: ...INSTALLATION MANUAL Cabinet Side View Cabinet Door Nut Spacer Spacer Screw Spacer Install the wall tamper switch using the supplied bolts and nuts as shown in the following picture Install the tamper...

Страница 11: ...er switch to the bracket then mount the bracket on the mounting flange Door Tamper Switch Bracket Door Tamper Switch Mounting Flange Install the door tamper switch by aligning the switch holes to the...

Страница 12: ...oor 1 Remove the box door knock out 2 Insert the lock in the hole 3 Slide the U metal bracket into the lock groove as shown in the picture to secure the lock in place Alternatively or complementary to...

Страница 13: ...NSTALLATION MANUAL Fixing the Box to its Location Install the box to its location using 4 screws not supplied as shown in the following picture If the wall tamper switch is used make sure that the tam...

Страница 14: ...e Integration Module Control up to 10 Schlage Door Handles INSTALLATION MANUAL Installing the ADH10 Controller Install the 5 supplied PCB fasteners in the holes identified in red in the images below L...

Страница 15: ...POWER SUPPLY BATT TAMPER ADH10 LOCAL BUS to ADH10 Door Handle Controller GWE NDE Lock Gateway or GND TDA TDB AD 300 GND RDA RDB PIM400 485 12V GND Rx Tx You can connect up to 10 GWE gateways or PIM40...

Страница 16: ...ch terminal and the other end to the wall tamper switch terminal 2 Connect the other terminal of the door tamper switch to the TMP terminals using the supplied wire 3 Connect the other terminal of the...

Страница 17: ...s identified as shown in the following picture 2 Connect the pre installed green power LED to the ADH10 Controller DC Power Supply and terminals in parallel with the AC DC power supply The red wire go...

Страница 18: ...he fuse using the same fuse type 250VAC 2 5 A Time Lag Slow Blow Operating Temperature 55o C to 125o C Permitted replacements a Littelfuse P N 021802 5MXP b Schurter P N 0034 3121 c Various means any...

Страница 19: ...d terminals with the battery leads supplied 12Vdc 7Ah rechargeable acid lead or gel cell backup battery UL ULC YUASA NP7 12 recommended Europe CDVI B7AH recommended Ensure proper polarity Various mean...

Страница 20: ...mitted received Green LED LINK Ethernet network detected Green LED 2 COM PORT AUX Green LED 12 V output power activated RX Green LED flashing Data received on local bus TX Green LED flashing Data tran...

Страница 21: ...ireless Lock NDE Wireless Lock PIM400 485 Panel Interface Module GWE Gateway Each PIM400 485 or GWE can manage up to ten locks ADH10 can manage up to ten PIM400 485 and or GWE ADH10 firmware version 3...

Страница 22: ...ay not be held responsible in the event of loss or non presentation of the form The 5 Year Warranty only applies to products installed by a skilled and experienced personal with the necessary trade qu...

Страница 23: ...elements considered as consumables such as fuses lights and batteries for example Failure or malfunctioning as a result of an accident poor storage conditions unsuitable assembly bad utilization or h...

Страница 24: ...Phone 1 450 682 7945 Fax 1 450 682 9590 CDVI BENELUX BELGIUM NETHERLAND LUXEMBOURG Phone 32 0 56 73 93 00 Fax 32 0 56 73 93 05 CDVI TAIWAN Phone 886 0 42471 2188 Fax 886 0 42471 2131 CDVI SUISSE Phone...

Отзывы: