15
cdvigroup.com
EN
ADH10
ATRIUM - Schlage Integration Module (Control up to 10 Schlage Door Handles)
INSTALLATION MANUAL
EN
ADH10
ATRIUM - Schlage Integration Module (Control up to 10 Schlage Door Handles)
INSTALLATION MANUAL
5] WIRING DIAGRAM
Connecting ALLEGION GWE gateway, PIM400-485 or AD-300
Connect ALLEGION GWE gateway, PIM400-485 or AD-300 on a 3 conductor RS485 communication loop in daisy
chain or star configuration up to 1220m (4000 ft) from the ATRIUM ADH10 controller.
LOC
AL
BUS
POWER SUPPL
Y
BAT
T.
TA
MPER
ADH10 LOCAL BUS to
ADH10
Door Handle Controller
GWE
NDE Lock Gateway
or
GND
TDA-
TDB+
AD-300
GND
RDA-
RDB+
PIM400-485
12V
GND
Rx+
Tx
-
You can connect up
to 10 GWE gateways
or PIM400-485 to the
ADH10 RS-485 bus.
The ADH10 can manage
up to 10 door handles
Once the connection is properly done as shown above, the ATRIUM ADH10 will automatically detect
the Allegion GWE gateway, AD-300 or PIM400-485 on power on.
The ADH10 can provide power to up to four GWE Gateways and/or PIM400-485.
Use the supplied GWE transformer to power additional gateways on the same ADH10.