Pocket Quick 

 Reference Guide 

On the

 

TOSHIBA

 

Air to Air Heat Exchanger 

VN-M####HE/HE1 

Содержание VN-M Series

Страница 1: ... is correct and error free however we cannot guarantee that it is free of inaccuracies errors or omissions Users should seek to clarify this information for themselves prior to basing any decisions upon such information Pocket Quick Reference Guide On the TOSHIBA Air to Air Heat Exchanger VN M HE HE1 ...

Страница 2: ...imer ONLY remote controller Units can be group controlled either specifically air to air up to 8 units within a group or air to air units can be incorporated into an air conditioning group The units can also be controlled via any of the Central control or BMS options In short all the options available for standard Toshiba air conditioning equipment are also available for air to air products The ra...

Страница 3: ...Users should seek to clarify this information for themselves prior to basing any decisions upon such information Installation Duct connections 150 100mm 250 150mm 350 150mm 500 200mm 650 200mm 800 250mm 1000 250mm NOTE Duct connections Outdoor side 283 x 730mm Duct connections Indoor side 250mm Duct connections 150 100mm 250 150mm 350 150mm 500 200mm 650 200mm 800 250mm Installation VN M 1500 and ...

Страница 4: ...pply is applied to terminals L N E Without heater kit Local controllers are connected to terminals A B Central controllers BMS gateways are connected to terminals U3 U4 When being used as an Individual unit bit switch SW703 bit 4 must be turned to the ON position factory default is OFF HE models ONLY Slightly different set up for the HE1 models When being used as an individual unit Link CN71 must ...

Страница 5: ...wo and two banks of four SW301 Terminal End of Line resister ON 100Ω OFF None SW701 Pulse Static ON Pulse OFF Static SW702 1 to 4 Indoor unit address See chart SW703 1 to 2 Indoor unit address Factory default ALL OFF indoor address No 1 3 Central controller address ON Fix OFF Auto Leave value OFF 4 ON Header Individual OFF Follower Factory default follower A group can comprise of up to 8 units of ...

Страница 6: ...nformation for themselves prior to basing any decisions upon such information VN M units default to system number 31 this cannot be adjusted Examples Multiple units within a group Single VN M unit with local remote SW301 1 2 OFF SW701 1 2 OFF SW702 1 to 4 OFF SW703 1 to 2 OFF SW703 3 OFF SW703 4 ON Controller would display 1 1 31 2 1 3 31 4 1 5 Red System i e Outdoor unit Black indoor address Note...

Страница 7: ...y automatic with CN71 link removed on the header apply power to the units within the Group addressing will be carried out automatically If manual addressing is required Using the RBC NRC01HE remote controller with power on Press and HOLD for 4 seconds TEST SET and CL The controller will display 10 on the right hand display Using the Temp up down buttons scroll 10 to 13 Change the left hand display...

Страница 8: ...n used with VNM units the following functions are available The following remote controllers are not suitable for connecting on a One to One basis ON OFF Fan Speed High Low Ventilation mode Automatic Heat Exchanger Bypass Timer OFF Repeat OFF ON timer 168 hours in hr increments NOT clock based NO day omit available Sleep Timer This controller can also be used to control standard air conditioning u...

Страница 9: ...HE models CN705 connector on the main PCB B For the HE1 model CN61 on the Control PCB A If the lead is used with a remote controller it will operate in last one touched mode If the VN M units are grouped the lead can be connected to any VN M unit in the group Please see Installation manual supplied with the VN M unit for details When connected to the HE models VN M150 250 350 500 650 800HE Remove ...

Страница 10: ...n for themselves prior to basing any decisions upon such information When connected to the HE1 models VN M1000 1500 2000HE1 This must be connected to the CN61 socket on Control PCB A MCC 1643 there are two Control PCB s the A board has the temperature sensors connected to it The functionality of the VML1 interface is slightly different when used on the HE1 models The functions available are Note T...

Страница 11: ... Heater ONLY There are four options available Currently there are NO Pre Heater kits available for the VN M1500HE1 or the VN M2000HE1 units Each heater option requires a controller RBC VNMC The heater will only operate when the temperature of the air in the duct is below the pre set value The controller will also provide a run on when the unit stops The controller is class 1 and MUST be earthed Ge...

Страница 12: ...at it is free of inaccuracies errors or omissions Users should seek to clarify this information for themselves prior to basing any decisions upon such information Wiring For full technical details please refer to the relevant manuals available for this product THE HEATER CONTROLLER AND THE HEAT EXCHANGE UNIT MUST BE SUPPLIED FROM THE SAME PHASE AND SUPPLY ...

Страница 13: ...re are a number of options available for time switch control Option 1 TCB EXS21TLE 7 day weekly schedule timer complete with day omit used in conjunction with the RBC NRC01HE remote controller Option 2 RBC SMT1 timer interface lead connects in the rear of the RBC NRC01HE via the CN02 connector and provides an external volt free switching circuit for connection to a third party timer Option 3 RBC V...

Страница 14: ...inaccuracies errors or omissions Users should seek to clarify this information for themselves prior to basing any decisions upon such information Advanced Functions There are a number of advanced facility functions which are available configuration of these facilities functions is carried out via the RBC NRC01 local remote controller The facilities functions available are ...

Страница 15: ...s will be displayed on the right hand side of the display 3 If you wish to change the Data Displayed on the left hand side of the display use the TIME UP DOWN buttons 4 Once you have the required data on the left hand display Press SET 5 If there are a number of units controlled via the same controller and you wish to change their Data then press the UNIT button the middle window will change and t...

Страница 16: ... decisions upon such information Contact details Cool Designs Ltd Technical Support 07590 775510 07706 293028 Monday Friday 07 30 to 19 30 Email support cooldesignsltd co uk Web site www cdlweb info Toshiba Air Conditioning 24 7 technical support 0870 843 0333 Option 7 Text back service 07624 803 017 Type fault code in lower case no spaces Try our on line training videos on YouTube Cool Designs Lt...