7
1.
Clear Button (quadrature devices only) –
Press and Hold the Clear Button to zero
the displayed measurement for that channel.
2.
Hold Button (quadrature devices only) –
Press Hold to toggle on or off hold function.
To enable/disable Hold function and configure (Min, Max, or Freeze) see setup
functions under Gage Functions.
3.
Log Data Button –
Press to record current measurement
4.
Request Button (Digimatic devices only) –
Press to request reading from selected
channel
5.
Clear All Button –
Press to zero all quadrature channels
6.
Request All Button –
Press to request reading from all Digimatic channels
7.
Log All Button –
Press to record current measurement for all channels
Configuring Channels
Regardless of the connected gage type, all channels have a set of common settings. To
access the settings for a given channel, swipe from the left side of the screen towards the
center of the tablet.
Alternatively, press the back button on the tablet’s soft key menu), and then click on the
name of the appropriate channel.
Apart from the type of connected device (Quadrature or Digimatic) there are several
settings that are always available. These settings are summarized in the following list:
Setting
Notes
Channel Enabled
Enables/Disables channel. Disabling a channel will hide it from the main
display.
Gage Type
Selects the channel function between Quadrature and Digimatic modes.
Unit Type
Selects measurement unit between Inch, Millimeter, and Hidden.
Mode
Selects indication mode between Incremental (default), Absolute, and Total
Indicated Runout (TIR). TIR is only available for Quadrature Devices.
Absolute Offset
Entry of absolute offset (ABS mode only).
Travel Direction
Selects between forward and reverse travel direction.
Tolerance
Enables/Disables tolerance mode. If this mode is enabled, the analog
indication for this channel will turn red when the measurement falls outside
of the specified bounds.
High Tolerance
Sets the maximum allowable high tolerance value for this channel.
Low Tolerance
Sets the maximum allowable low tolerance value for this channel.
Ratio Mode
Enabling Ratio mode will scale the current value by the value of the “Ratio
Value” setting.
Ratio Value
Scale multiplier for current gage measurement.
Automatic Log
Enables automatic data logging at an interval.
Log Interval (s)
Sets the logging interval if Automatic Log is enabled.
Show Analog Scale
Enables display of the analog scale in addition to the readout value.
Analog Scale
Selects the maximum value to display on the analog scale readout.
Show Leading Zero
Enables/Disables leading zeros on current measurement.
Содержание EMS 4
Страница 1: ...1 Remote Display User Manual ...
Страница 10: ...10 ...
Страница 17: ...17 Find the preferred cloud storage service and follow the instructions to save the logs ...
Страница 20: ...20 ...
Страница 21: ...21 Digimatic Data Format ...
Страница 26: ...26 6 Select Advanced Options from the Troubleshoot menu 7 Select Startup Settings ...