Parameter List
The following list summarizes the configuration parameters available for configuring each
device channel. When editing these values over RS-232 and/or USB, make sure to hit the
Save command to commit the values, otherwise, they will be reset if the Remote Display is
powered down.
Parameter
Description
Values
p003
p004
Channel Enabled
Units
0 – No
1 – Yes
1 – Inches
2 – Millimeters
3 – Hidden
p005
Measurement Mode
0 – Absolute (ABS)
1 – Total Indicated Runout (TIR)
2 – Incremental (INCR)
p006
Travel Direction
0 – Normal
1 – Reverse
p007
Hold Enabled
0 – Disabled
1 – Enabled
p008
Hold Mode
0 – Freeze
1 – Min
2 – Max
p009
Tolerance Enable
0 – Disabled
1 – Enabled
p910
Upper Tolerance
Enter value without decimal
Ex: 012345 = 0.12345
p911
p914
Lower Tolerance
Absolute Offset
Enter value without decimal
Ex: 012345 = 0.12345
Enter value without decimal
Ex: 012345 = 0.12345
p016
Gage Type
0 – Digimatic
1 – Encoder
p017
Glass Type
(encoders only)
1 – Inches
2 – Millimeters
p018
Base Multiplier
(one encoder tick)
5 – 0.00005”
10 – 0.001”
100 – 0.001mm
200 – 0.002 mm
p019
Ratio Mode Enabled
0 – Disabled
1 – Enabled
p020
p921
Ratio Multiplier
Analog Scale
Enter value without decimal
Ex: 012345 = 0.12345
Enter value without decimal
Ex: 012345 = 0.12345
p023
Gage Resolution
1 – 0.001” or 0.02mm
2 – 0.0005” or 0.01mm
3 – 0.0001” or 0.002mm
4 – 0.00005” or 0.001mm
p024
Leading Zero
0 – Disabled 1 – Enabled
Содержание EMS 4
Страница 1: ...1 Remote Display User Manual ...
Страница 10: ...10 ...
Страница 17: ...17 Find the preferred cloud storage service and follow the instructions to save the logs ...
Страница 20: ...20 ...
Страница 21: ...21 Digimatic Data Format ...
Страница 26: ...26 6 Select Advanced Options from the Troubleshoot menu 7 Select Startup Settings ...