CD52 Bandit (ATEX-IECEx Certification) User Guide
Page 33 of 48
OPTIONAL EQUIPMENT
OPTIONAL EQUIPMENT
Remote Indicator System (RIS)
The Remote Indicator System
(RIS) consists of four high-
luminosity LEDs that, when pig
passage occurs, can be seen over
distances as great as 100 meters
(328 ft].
The RIS may be added to any
Bandit System.
Cathodic Protection Base Mounting
Cathodic protection insulation matting
is available to protect pipeline coating.
Heater
A 24 VDC internal heater is available
and recommended for operation
in temperatures below –30°C [–22°F].
Heat Risers
Heat riser insulators for the CD52 Bandit allow the system to be used
on geothermal pipeline, or other environments where pipeline surface
temperatures exceed of 80°C [176°F].
NOTE: Heat risers enable the CD52 Bandit to operate with product
temperatures greater than 80°C [176°F]. However, if the
ambient air
environment
of the system is
greater
than 70°C [158°F], it will be operating
outside of ATEX/IECEx Certification.