INSTALLATION
Armored Flex Cable Units
Bandit units configured with armored flex cable are shipped mounted
on a plywood sheet with webbing straps. Special unpacking procedures
should be followed:
Required tools/materials:
• Screw gun or Phillips
screwdriver
• Banding kit (supplied)
• Batteries (supplied)
1. Lift mounted assembly
with webbing handles only.
2. Remove antenna base unit strap
using Phillips screw driver.
3. Uncoil cable.
This requires
two (2) personnel. Person #1 will
hold antenna base (while supporting
cable) and walk in an ever-widening
circle. While walking, Person #1 will
continually untwist the antenna base
to prevent cable from kinking.
Person #2 will be responsible for uncoiling cable at the plastic spool.
4. Startup procedure
is identical to that of standard units.
NOTE: Prepare
an unobstructed
6 m x 6 m [20 ft x 20 ft]
area before unpacking.
NOTE: Maintain a 152 mm [6 in.] minimum bend radius
to avoid kinking or breaking the aluminum cable armor.