2 / INSTALLING YOUR APPLIANCE
Warning:
Ensure that your appliance has not suf-
fered any damage during transport
(deformed seal or door, etc...). If you see
any kind of damage, before doing anything
else, contact your retailer.
In order to easily locate the reference infor-
mation for your appliance, we recommend
that you note these data on the “After-Sales
Service Department and Customer
Relations” page.
Ensure that:
- The electrical installation has sufficient volt-
age.
- The electrical wires are in good condition.
- The diameter of the wires complies with the
installation requirements.
- Your electrical installation is equipped with
16-ampere thermal-sensitive protection.
In case of doubt, consult your electrician-
installer.
The electrical connections are made before
the appliance is installed in its housing.
Electrical safety must be provided by a cor-
rect build-in. During installation and mainte-
nance operations, the appliance must be
unplugged from the electrical grid; fuses
must be cut off or removed.
The oven must be connected with a power
cable (standardized) with three 1.5 mm² con-
ductors (1 ph +1 N + ground) that must be
connected to a monophase 220-240 V net-
work via a CEI 60083 standardised receptacle
(1 ph +1 N + ground lead) or in accordance
with installation rules. The safety wire (green-
yellow) is connected to the
appliance’s
ground terminal.
In the case of connections with an electric
receptacle, it must remain accessible after
installation of the appliance.
The oven’s neutral conductor (blue wire)
must be connected to the network’s neutral
conductor.
In your electrical installation, allow for a user-
accessible device that must be able to sepa-
rate the appliance from the main power sup-
ply and whose contact opening is at least
3 mm above all the terminals.
If the power cable is damaged, it should be
replaced by the manufacturer, its after-sales
service department or by a qualified person
to avoid danger.
Warning:
We cannot be held responsible for any
accident resulting from an non-existant,
defective or incorrect ground lead.
If the oven malfunctions in any way, unplug
the appliance or remove the fuse corre-
sponding to the sector there the oven is
hooked up.
•
BEFORE HOOK-UP
•
ELECTRICAL CONNECTIONS