LIGHTING THE BURNERS

To ignite the burner, the following instructions 

are to be followed:
1.  Press in the corresponding knob and turn 

counter-clockwise (fig. 6) to the full flame 
position marked by the “

” symbol (fig. 

5); hold the knob in until the flame has 

been lit. 

 

In the case of a mains failure light the 

burner with a match or lighted taper.

2.  Wait for a few seconds after the gas 

burner has been lit before letting go of 

the knob (valve activation delay).

3.  Adjust the gas valve to the desired 

position.

If the burner flame should go out for some 

reason, the safety valve will automatically 

stop the gas flow.

To re-light the burner, return the knob to 

the closed “   ” position,

 wait for at least 

1 minute 

and then repeat the lighting 

procedure.

Note: 

If your local gas supply makes it 

difficult to light the burner with the knob set 

to maximum, set the knob to minimum and 

repeat the operation. 

NOTE: The knob and symbols may vary.

Fig. 6

Содержание HCG302

Страница 1: ...www cda eu HCG302 Built in Gas Cooking Hob Installation Use and Maintenance GB IE...

Страница 2: ...sposal of the Product in Accordance with EC Directive 2012 19 EC At the end of its working life the product must not be disposed of as urban waste It must be taken to a special local authority differe...

Страница 3: ...ese parts are within the limits allowed by the norms The complete safety of the appliance also depends on the correct use we therefore recommend to always pay a extreme attention while using the produ...

Страница 4: ...in accordance with the regulations in force in your country If the appliance is to be scrapped remove the power cord After use ensure that the knobs are in the off position Children less than 8 years...

Страница 5: ...r intended to be touched and may contain sharp or rough edges that may cause injury CAUTION The cooking process has to be supervised A short term cooking process has to be supervised continuously If t...

Страница 6: ...rners USE OF THE APPLIANCE ENERGY SAVING TIPS HOB GAS FIRED BURNERS It is important that the diameter of the pot be suitable to the size of the burner so as not to compromise the high output of the bu...

Страница 7: ...7 ADVICE ADVICE for the for the INSTALLER INSTALLER...

Страница 8: ...and in observation of the manufacturer s instructions Installation technicians must comply to current laws in force concerning ventilation and the evacuation of exhaust gases Incorrect installation fo...

Страница 9: ...or drawer space after installation a thermal protection barrier is not required If the cooktop is installed above an oven the two appliances shall be connected to the gas and or electrical supply with...

Страница 10: ...10 Measures mm Description A B C D E F minimum G minimum 30cm wide models 288 510 30 270 490 50 100 650 mm 450 mm min 200mm 500 mm E F D G B A C Fig 2 Cooktop installed min 100 mm Fig 1...

Страница 11: ...to overlay the junction edges fig 4 Turn the cooktop over and put tabs A fig 3 into the mountings only tighten screws B a few turns Make sure that the tabs are mounted correctly as shown in the figure...

Страница 12: ...ea will be required unless the room has a door which opens directly to the outside air in which case no permanent ventilation is required For rooms with a volume greater than 10 m3 no permanent ventil...

Страница 13: ...ification The appliances are manufactured for conversion to NATURAL GAS If the NATURAL GAS LPG conversion kit is not supplied with the appliance this kit can be purchased by contacting the After Sales...

Страница 14: ...such installation of gas appliances Note It is recommended that the gas connection to the appliance is installed with a flexible hose connecting tube made to BS669 or EN 14800 Notes Flexible hoses ca...

Страница 15: ...o the appliance connecting pipe shall be of a sufficient size to maintain the heat output of the appliance as specified on the rating plate 1 The appliance flexible connector should not be subject to...

Страница 16: ...ESSARY FOR GAS COMBUSTION 2 m3 h x kW BURNERS Air necessary for combustion m3 h Semi rapid SR 3 50 Rapid R 6 00 Triple ring TR 7 60 GAS MAINTENANCE LUBRICATION OF THE GAS TAPS In case of difficulty in...

Страница 17: ...ubstitute the injectors J figs 8 9 with those most suitable for the kind of gas for which it is to be used The burners are conceived in such a way so as not to require the regulation of the primary ai...

Страница 18: ...the following code Green Yellow Earth Blue Neutral Brown Live As the colours of the wires in the mains lead for the appliance may not correspond with the coloured markings identifying the terminals c...

Страница 19: ...19 ADVICE ADVICE for the for the USERS USERS...

Страница 20: ...20 Fig 1 Fig 3 Fig 2 Fig 4 Features and Technical Data 6 5 4 1 2 3 5 4 1 2 6 3 6 5 4 1 2 3 5 4 1 2 6 3 NOTE The knobs and symbols may vary Caution Do not cover the hob with aluminium foils...

Страница 21: ...o out CAUTION If the burner is accidentally extinguished turn the gas off at the control knob and wait at least 1 minute before attempting to re light CAUTION Gas hobs produce heat and humidity in the...

Страница 22: ...liquids To reduce the gas flow to minimum rotate the knob further anti clockwise to point the indicator towards the small flame symbol Other intermediate operating adjustments can be achieved by posit...

Страница 23: ...nds after the gas burner has been lit before letting go of the knob valve activation delay 3 Adjust the gas valve to the desired position If the burner flame should go out for some reason the safety v...

Страница 24: ...ex bases It is important that the diameter of the pot be suitable to the potentiality of the burner so as not to compromise the high output of the burners and therefore energy waste A small pot on a l...

Страница 25: ...e appliance it is available as an accessory at extra cost in order to avoid any faulty operation of the triple ring burner figs 8a 8b 9a 9b The flat bottomed pans are to be placed directly onto the pa...

Страница 26: ...tain types of sponge and or aggressive products e g caustic soda products containing corrosive substances which could cause irreparable surface damage WARNING When correctly installed your product mee...

Страница 27: ...rouble free sparking Check that the probe s T figs 10 12 next to each burner is are always clean to ensure correct operation of the safety valves Both the probe and ignition plug must be very carefull...

Страница 28: ...28 Fig 11 Fig 12 Fig 13 Fig 14 S F C T A B S T Fig 10...

Страница 29: ...29...

Страница 30: ...ng information available when booking a service call 1 Model type make and model see the product data plate 2 Evidence of installation purchase date 3 Retailer where appliance was purchased 4 Clear an...

Страница 31: ...31...

Страница 32: ...epartment The Group Ltd Harby Road Langar Nottinghamshire NG13 9HY T 01949 862 012 F 01949 862 003 E customer care cda eu Copyright CDA 2017 www cda eu Please contact our Customer Care Department for...

Отзывы: