14
GAS CONNECTION
GB
Cat:
II
2H 3+
Installation to Natural Gas
Installation to Natural Gas must conform to the Code of Practice, etc.
The supply pressure for Natural Gas is 20 mbar.
The installation must conform to the relevant British/European Standards.
Installation to LP Gas
When operating on Butane gas a supply pressure of 28-30 mbar is required.
When using Propane gas a supply pressure of 37 mbar is required.
The installation must conform to the relevant British/European Standards.
Warning:
Only a suitably qualified and registered installer, also with technical knowledge of
electricity should install the appliance.
He should observe the Regulations and Codes of Practice governing such installation of gas
appliances.
Note: It is recommended that the gas connection to the appliance is installed with a flexible hose
connecting tube made to BS669 or EN 14800.
Notes:
•
Flexible hoses can be used where the sited ambient temperature of the hose does not
exceed 70°C. These hoses must be manufactured in accordance with BS669 part 1 or EN
14800 and be of the correct construction for the type of gas being used.
•
Gas hoses designed for natural gas MUST NOT be used for supplying LPG gas (LPG gas
hoses can be identified by a either a red band or stripe on the rubber outer coating of
the hose).
The hose should not be crushed or trapped or be in contact with sharp or abrasive
edges.
IMPORTANT! It is the responsibility of the gas installer to ensure that the product is fully
tested and commisioned in accordance with current regulations to ensure there are no gas
escapes.
IE
Содержание HCG302
Страница 1: ...www cda eu HCG302 Built in Gas Cooking Hob Installation Use and Maintenance GB IE...
Страница 7: ...7 ADVICE ADVICE for the for the INSTALLER INSTALLER...
Страница 19: ...19 ADVICE ADVICE for the for the USERS USERS...
Страница 28: ...28 Fig 11 Fig 12 Fig 13 Fig 14 S F C T A B S T Fig 10...
Страница 29: ...29...
Страница 31: ...31...