17
Mains Electricity
Connection
Warning! This appliance must be
earthed.
This appliance must be connected by
a qualified electrician, or a similarly
competent person, who is a member of
the N.I.C.E.I.C. and who will comply with
the I.E.T. and local regulations.
This appliance is intended to be
connected to fixed wiring and is not
suitable for connection to a 13A plug
or 13A supply.
E
Y
N
G
U
B
N
B
Live L: BN - brown
Neutral N: BU - blue
Earth PE: GNYE -green/yellow
L N
Fig. 11
This appliance is intended to be connected to fixed wiring by a
double pole switch, having a contact separation of at least 3mm in
all poles. The switch must be positioned no further than 2m from
the appliance.
Please note:
•
The mains cable must only be replaced by a qualified electrician
or service engineer and must be of equivalent or better rating (i.e.
4mm2, HO5VV-F).