background image

13

Using the template supplied, drill out the mounting screw holes, the 
ducting outlet and a route for the mains lead, if required. Attach the 
ducting adapter, supplied with the appliance, to the extractor.

Remove the grease filters to stop them being damaged. Attach the 
ducting to the extractor and then fit the extractor into the unit, routing 
the ducting first. Whilst the person helping is supporting the unit, fit 
four screws through the unit shelf and into the extractor top. Ensure 
that the extractor is firmly in position and re-fit the grease filters. 

A bracket has been supplied to cover a gap between the unit/wall 
and the back of the extractor. This attaches to the extractor via holes 
near the lamp covers and then to the unit/wall. It offers adjustment.

Please note:

 If you are recirculating the air back into the kitchen, 

then ducting should be used to channel the air out of the unit. An 
example is shown below in Fig. 4. A non-return flap or similar should 
be employed to prevent debris etc. falling into the ducting.

Fig. 4

Ducting out

Recirculating

Vent, grille 
or similar 
non-return 
mechanism

Содержание CTE61

Страница 1: ...www cda eu CTE61 Extractor Installation use and maintenance...

Страница 2: ...Using your extractor 7 Care and maintenance 9 Troubleshooting 10 13 Installation 10 Installation height 11 Installation preparation and ducting 12 Installation mounting the extractor 14 Mains electri...

Страница 3: ...bout it unless they have had supervision or instructions on how to use the appliance by someone who is responsible for their safety Under no circumstances should any external covers be removed for ser...

Страница 4: ...al local authority waste collection centre or to a dealer providing appliance recycling services Disposing of a household appliance separately avoids possible negative consequences for the environment...

Страница 5: ...he extractor in It should be removable for service or maintenance Do not use silicone sealant to secure the hood to the wall You must be able to isolate the extractor from the mains electrical supply...

Страница 6: ...e open the canopy and activate either switch B or switch C Fig 1 Switch B the left speed switch has three positions speed 1 speed 2 and off Switch C the right speed switch has two positions speed 3 an...

Страница 7: ...PPLY Cleaning You should use a nonabrasive cleaner Any abrasive cleaner including Cif will scratch the surface and could erase the control panel markings You can clean your extractor effectively by si...

Страница 8: ...appliance Changing the charcoal filter re circulating mode only To ensure best performance of your extractor you should replace the charcoal filters every four to six months depending on use The char...

Страница 9: ...ractor is not working 1 Check that the mains supply has not been switched off 2 Check that the fuse in the spur has not blown 3 Check that a speed switch is active and the canopy is open If your light...

Страница 10: ...ce that should be observed this is a legal requirement and may lead to your hob being disconnected from the gas supply and the installation being reported under RIDDOR Note The height should be measur...

Страница 11: ...15mm may reduce performance and increase the noise of the extractor Wherever possible use rigid circular pipe which has a smooth interior rather than the expanding concertina type ducting The lengths...

Страница 12: ...mplate supplied with the appliance In the unlikely event of the template being missing the below measurements may aid you To achieve a flush fit with a decor door on the bridging unit adjust the depth...

Страница 13: ...and into the extractor top Ensure that the extractor is firmly in position and re fit the grease filters A bracket has been supplied to cover a gap between the unit wall and the back of the extractor...

Страница 14: ...cordance with the following code Green Yellow Earth Blue Neutral Brown Live As the colours of the wires in the mains lead for the appliance may not correspond with the coloured markings identifying th...

Страница 15: ...ion should be carried out by specialised personnel The isolation switch and fuse for this appliance should be easily accessible after installation is complete Electrical information Mains electrical v...

Страница 16: ...16 NOTES...

Страница 17: ...17 E O E All instructions dimensions and illustrations are provided for guidance only CDA reserve the right to change specifications without prior notice NOTES...

Страница 18: ...9HY T 01949 862 012 F 01949 862 003 E customer care cda eu For service or queries relating to your product please contact The Customer Care Department on 01949 862 012 or email customer care cda eu Fo...

Отзывы: