background image

33

4

Manual Control

Inputting an External Trigger

Refer to 7. Signal Input Sequence for the sequence diagram.

5

Locking Settings

When the setting switch is pressed for 

2 seconds or longer, the lighting mode and 

light intensity settings are locked, and 

the LOCK setting indicator lights. (The set 

values can be viewed.) Pressing the switch 

again for 2 seconds or longer releases the lock.

2

Selecting the Channel

Press the channel selection switch to select the 

channel to set (L1 to L3). The channel indicators 

will change.

3

Setting the Light Intensity

Press the setting switch to light the BRT setting 

indicator.

Turn the setting switch to set a value between 0 and 255.

(Default setting: 000, Minimum: 000, Maximum: 255)

* The Light Units are light dimly at the minimum value.

1

Setting the Manual/External Mode 

Selector to Manual

Set the Manual/External Mode Selector to MANU 

to set Manual Mode.

Make sure that the LOCK setting indicator is not light and that the trigger 

logic switch is set to HIGH. Otherwise you may not be able to perform the 

rest of this procedure.

Check

4

Selecting the Lighting Mode

Press the setting switch to light the PLS 

setting indicator.

Turn the setting switch to select the lighting 

mode from Continuous Mode, ON/OFF Mode, 

or Strobe Mode.

(Default value:  F00   )

Continuous Mode

Turn the setting switch and set  F00   to 

turn ON the Light Units continuously.

ON/OFF Mode

(If the external trigger is not used, the Light Units are ON continuously.)

Turn the setting switch and set   F00    to turn the Light Units ON and OFF.

The Light Units are turned ON or OFF according to the external trigger signal input.

Strobe Mode

(If an external trigger is not used, the Light Units are OFF.)

To flash the strobe, turn the setting switch and 

select a setting from   F01 to F10 

(strobe time of 40 μs to 40 ms).

The Light Units are turned ON for the period of time set 

on the setting switch after the external trigger signal is input.

For details on the external trigger input, refer to 8. Inputting the External Trigger.

Digital display

F00

F01 F02 F03 F04 F05 F06 F07 F08 F09 F10

40 μs 80μs 120 μs 200 μs 600 μs

Strobe Mode

1 ms 4 ms 10 ms 20 ms 40 ms

Continuous Mode

ON/OFF Mode

Status

Make sure that the main power source is turned ON.
Set items       ,      , and       when using Continuous Mode or ON/OFF Mode.
Set items       ,      ,      , and       when using Strobe Mode.

1

3

4

2

1

3

2

Input Signal and Photocoupler

The input signal from the external trigger input connector can be used to control 

the photocoupler inside the Unit to turn the LED Light Units ON and OFF or to 

control strobe timing.

The operation depends on the setting of the trigger logic switch.

Setting Procedures

With the external trigger input connector pins 1 

to 3, select the channels (L1 to L3) where you 

want to input an external trigger, and input the 

trigger.

Connector Layout

External Trigger Signal Connection Example

Trigger signals are input from the external trigger 

input connector in ON/OFF Mode and Strobe 

Mode are regardless of either Manual Mode or 

External Mode.

ON/OFF Mode

The Light Units are turned ON or OFF according to 

the external trigger signal input.

Strobe Mode

The Light Units are turned ON for the set time 

after the external trigger signal is input.

9 7 5 3 1

10 8 6 4 2

1

2

3

Trigger Logic 

Switch

ON/OFF 

Mode

Input signal

HIGH

OFF

Light Units ON

Light Units ON for the set time.

LOW

ON

Light Units OFF

No change

HIGH

OFF

Light Units OFF

No change

LOW

HIGH

LOW

ON

Light Units ON

Light Units ON for the set time.

Photocoupler

Strobe Mode

External Trigger Input Connector Plug

Enlarged Cable Diagram

Rated input voltage: 24 VDC
Maximum input voltage: 26.4 VDC
ON voltage/ON current: 14.4 VDC min./3 mA max.
OFF voltage/OFF current: 5 VDC max./1 mA max.

 

ON/OFF response time: 10 µs max.

 

Input impedance: 12 kΩ (per terminal)

 

Signal Specifications

Pink

Red 1

Example: Pin No. 10, pink, red 1

Light Unit ON/OFF 

control input

L1

24 VDC

Transistor (NPN) 

open collector

Transistor (NPN) 

open collector

Transistor (NPN) 

open collector

PD3 Control Unit

External Circuits

L3

L2

10

1

2

3

10

()

Light Unit ON/OFF 

control input

Light Unit ON/OFF 

control input

No.

Wire color

Cable

(EXCB2-M10-3/EXCB2-M10M20-3)

Marks

Signal

Light Unit ON/OFF control input (L1)

Light Unit ON/OFF control input (L2)

Light Unit ON/OFF control input (L3)

Not used.

- - -

- - -

Orange
Orange

Gray

Pink

Black 1

Red 1

Black 1

Red 1

1
2
3

4 to 9

10

12kΩ

22kΩ

12kΩ

22kΩ

12kΩ

22kΩ