![CCL 216B Скачать руководство пользователя страница 8](http://html1.mh-extra.com/html/ccl/216b/216b_operating-and-programming-manual_2575818008.webp)
Dial #* 0000 + 883 NN XXXX#
Wher e, NN= last digit of Original Extensio n numb ers that is to be program m ed for this feature.
XXXX = Extensio n numb er to which call will land in Hotline
feature.. Dial #* 0000 + 884 NN # - To convert N Extensio n in normal mode.
Note
:
When all Extensi o ns are converted to Hot Line then to get into the Program mi ng mode, lift Hands et
– dial * # * 0000
+ whatev e r Program mi ng to be done.
Defaul t: All extensi o n is in Normal Mode.
.
Junction Access During Power Failure
.
When the system is switched OFF, the Junctio n lines get directly connec ted to following respec tiv e extensio ns .
Junctio n Numb er Extensi o n Numb er to which it gets connec ted
01 601
02 602
.
Junction Access Codes / Change
.
Junctio n lines can be access ed in rotatio n by dialing 0.
To access a particul a r junction line:
#11 - To access 1
st
Junctio n Line
#12 - To access 2
nd
Junctio n Line
The junctio n access code can be chang ed from 0 to 8. Refer heading
‘Junctio n Gro upi ng’ for proced ure.
.
Junction Access in Circular / Sequential Mode
.
In case of dialing out on the Junctio n Lines, PBX can be configured to work in either of the following 2 modes:
Mode Descri pti o n
Circul ar When an extensio n dials 0, the PBX will allot Junctio n numb ers 01.
Next time any Extensio n dial 0, Junctio n numb er 02 will be allotted. Then 01.
Sequenti al When an extensi o n dials 0, the PBX will allot Junctio n numb ers 01.
Next time any Extensio n dial 0 and if Junctio n 01 is free then Junctio n 01 will be allotted.
Junctio n numb er 02 will be allotted only when Junctio n 01 is engag ed .
Program mi ng
:
To program in Circul ar mode,
Dial #* 0000 + 0620 #
To program in Sequenti al mode,
Dial #* 0000 + 0621 #
.
Junction Access Control
.
Every Extensio n can be program m ed to access Junctio n Line. The access to each Extensio n can be different in Day mode
and Night mode.
Proced ur e
:
Dial #* 0000 + 70 J NN X # (For Day Mode access )
Dial #* 0000 + 71 J NN X # (For Night Mode access )
Wher e
J = Junctio n Numb er (1 to 2)
NN = Last two digits of Original Extensio n Numb e r (01 to 12)
X = 0 to allow Junctio n access
1 to Disallow Junctio n access.
Dial #* 0000 + 70 J X # (To allow/dis all o w all extensio ns to access Junctio n in Day Mode)
Dial #* 0000 + 71 J X # (To allow/dis all o w all extensio ns to access Junctio n in Night Mode)
Defaul t: All extensi o ns are allowed to access Junctio n Line in both Day and Night mode.
.
Junction Dialing Controls
.
Junctio n dialing facility can be controll ed Extensi o n wise as below
:
Dial #* 0000 + 40 NN L #
where, NN= Last two digits of Extensio n numb e r.
L = 0 - The Extensio n can dial only the numb ers starting with digits defined in
“Allowed Table”
1 - The Extensio n can dial all numb ers .
2 - The Extensio n can dial all numb ers except for ISD numb e rs.
3 - The Extensio n can dial all numb ers except for STD numb ers .
4 - The Extensio n can dial all numb ers except for the numb ers starti ng with digits defined in
“Deni ed
Table-
A ”
5 - The Extensio n can dial all numb e rs except for the numb ers starti ng with digits defined in
“Deni ed
Table-
B ”
6 - The Extensio n canno t dial out but can make internal calls.
To give all extensio ns the same L value
:
Dial #*0000 + 40 L #
Note
:
In default: all extensi o ns are in L = 1 mode.