background image

12

TIME SERVER CONNECTION STATUS

After the console has connected to the Internet, it will attempt to 

connect to the Internet time server to obtain the UTC time . Once the 

connection succeeds and the console time has been updated, the “ 

 ” icon will appear on the LCD .

The time will automatically synchronize Internet time server at 12:00AM and 12:00PM per day . Also you 

can press the 

[ REFRESH ]

 key to get the Internet time manually within 1 minute . 

ADVANCE SETTING IN WEB INTERFACE

Press 

"ADVANCED"

 key at the top of web interface to enter the advance setting page, this page allow you 

to set and view the calibration data of the console, as well as update the fi rmware version on PC/Mac web 

browser .

Upload

Browse

Firmware version: 1 .00 

-560~ 560hpa / -16.54 ~ 16.54inHg / -420 ~ 420mmH

g

Setting Range:

Temperature

o

C

Outdoor

Indoor

CH 1

CH 2

CH 3

CH 4

CH 5

CH 6

CH 7

Humidity %

Relative Pressure Offset:

Absolute Pressure Offset:

hpa

Range: -20 ~ 20

(Default: 0 .0)

Current offset: 0

Current offset: 0

Current offset: 0

Current offset: 0

Current offset: 0

Current offset: 0

Current offset: 0

Current offset: 0

Current offset: 0

Current offset: 0

Current offset: 0

Current offset: 0

Current offset: 0

Current offset: 0

Current offset: 0

Current offset: 0

(Default: 0)
Current offset: 0

(Default: 0)

Current offset: 0

Current offset: 0

Current offset: 0

Pressure

Range: -20.0 ~ 20.

0

o

C

-36.0 ~ 36.

0

o

F (Default: 0 .0) 

*UV gain:

Range: 0.01 ~ 10(Default: 1.00)

Current gain: 1 .1

*Light gain:

Range: 0.01 ~ 10(Default: 1.00)

Current gain: 1 .1

* Depends on the model

*Wind speed gain:

*Wind direction:

*Rain gain:

Range: 0.5 ~ 1.5(Default: 1.00)

Range: -10 ~ 10(Default: 0

o

)

Range: 0.5 ~ 1.5(Default: 1.00)

Current gain: 0 .85

Current offset: 2

o

Current gain: 0 .75

SETUP

ADVANCED

Select setting unit

Press "SETUP" icon to

Setup page

Pressure calibration 

section

version

ADVAN ED page

Select setting unit

The rain, wind speed, UV and Light

calibration use gain method . The 

wind direction is +/- 10 offset .

Current offset value is the value

that you set before to offset the 

pressure reading .

SETTINGS

In/Outdoor & Ch 1~7 

temperature calibration 

section

In/Outdoor & Ch 1~7 

humidity calibration 

section

C

function only available 

in PC/Mac web browser

CALIBRATION

1 . 

User can input the off set and/or gain values for diff erent parameters while current off set and 

gain values are shown next to their corresponding blank .

2 . Once completed, press 

Apply

 at the bottom of the SETUP page

The current off set value will show the previous value that you entered, please input the new value in the 

blank if any changes needed, the new value will eff ective once you press 

Apply

 icon in SETUP page .

Содержание C6089A

Страница 1: ...WI FI weather station with 5 In 1 professional sensor Model C6089A User Manual...

Страница 2: ...DATA IN WEATHERCLOUD 13 FIRMWARE UPDATE 13 OTHER SETTING FUNCTIONS OF THE CONSOLE 14 MANUAL CLOCK SETTING 14 SETTING ALARM TIME 14 ACTIVATING ALARM AND TEMPERATURE PRE ALARM FUNCTION 15 MOON PHASE 15...

Страница 3: ...ntains a coin button cell battery If the coin button cell battery is swallowed it can cause severe internal burns in just 2 hours and can lead to death Keep new and used batteries away from children I...

Страница 4: ...7 CHANNEL key 8 BARO key 9 Table stand 10 Wall mounting holder 11 ALERT key 12 ALARM key 13 CLOCK SET key 14 HI LO AUTO key 15 C F slide switch 16 SENSOR WI FI key 17 Battery door 18 USB Power socket...

Страница 5: ...10 9 11 1 Antenna 2 Radiation shield Thermo hygro sensor 3 Mounting parts fit for 35 40mm diameter pole 4 Battery door 5 RESET key 6 Transmission status LED 7 Bubble level gradienter 8 Rain collector...

Страница 6: ...batteries according to the polarity indicated Screw the battery door compartment on tightly NOTE The red LED will begin flashing every 12 seconds Screw location 3 x AA batteries MOUNTING POLE AND DIR...

Страница 7: ...automatically start AP mode USB cable NOTE If no display appears on the LCD after you plug the adaptor press RESET key by using a pointed object TABLE STAND INSTALLATION The unit is designed for deskt...

Страница 8: ...less sensor e g soil moisture and pool sensor If you would like to pair up additional sensors please check with your retailer for more detail POINTING THE WIRELESS 5 IN 1 SENSOR TO SOUTH The outdoor 5...

Страница 9: ...click My Pro le button on the top to open the drop down menu and click My Weather Station 3 In My Weather Station page bottom press the Add New Device button to add your device 4 In step Select a Devi...

Страница 10: ...her information 3 select I Accept to accept Weather underground s privacy terms 4 click Next to create your station ID and key 2 2 3 4 1 7 Jot down Your Station ID and Station key for the further setu...

Страница 11: ...evices page click New to create new device 3 Enter all the information in Create new device page for the Model selection box select the W100 Series under CCL section For the Link type selection box se...

Страница 12: ...veral second to connect PWS XXXXXX PWS XXXXXX PC Windows 10 WI FI network interface Android WI FI network interface 4 Once connected enter the following IP address into your Internet browser s address...

Страница 13: ...display language Press to complete the setting Select router SSID for connection Enter new Station ID and Station key that assigned by Wundergriund Enter new Station ID and Station key that assigned b...

Страница 14: ...nt offset 0 Current offset 0 Default 0 Current offset 0 Default 0 Current offset 0 Current offset 0 Current offset 0 Pressure Range 20 0 20 0o C 36 0 36 0o F Default 0 0 UV gain Range 0 01 10 Default...

Страница 15: ...ou can also check Weather Underground web site to learn more about their mobile App for Android and iOS VIEWING YOUR WEATHER DATA IN WEATHERCLOUD 1 To view your weather station live data in a web brow...

Страница 16: ...information again Firmware update process have potential risk which cannot guarantee 100 success If the update fail please redo the above step to update again OTHER SETTING FUNCTIONS OF THE CONSOLE MA...

Страница 17: ...m time alarm sound will start Where it can be stopped by following operation Auto stop after 2 minutes alarming if without any operation and the alarm will activate again in the next day By pressing A...

Страница 18: ...will display Er for the corresponding channel 3 If the signal does not recover within 48 hours the Er display will become permanent You need to replace the batteries and then press SENSOR WI FI key to...

Страница 19: ...ight air 1 1 5km h Smoke drift indicates wind direction Leaves and wind vanes are stationary 1 3 mph 1 3 knots 0 3 1 5 m s 2 Light breeze 6 11 km h Wind felt on exposed skin Leaves rustle Wind vanes b...

Страница 20: ...ion between 18 1 C to 25 9 C where both wind and humidity are less significant in affecting the temperature the device will show the actual outdoor measured temperature as Feels Like Temperature DEW P...

Страница 21: ...e Since variation in atmospheric pressure greatly affected by weather it is possible to forecast the weather by measuring the changes in pressure TO VIEW THE BAROMETRIC PRESSURE IN DIFFERENT UNIT 1 In...

Страница 22: ...will also display the icon data records time date PAST 24 HOURS HISTORY DATA The console automatically stores the weather data of the past 24 hours 1 Press HISTORY key to check the beginning of the cu...

Страница 23: ...SNOOZE key to silence the alert alarm or let the alarm automatically turn off after 2 minutes NOTE Once the alert is triggered the alarm will sound for 2 minutes and the related alert icon and readin...

Страница 24: ...e channel selection on sensor 3 If it still not work reset the sensor and resynchronize with console No WI FI connection 1 Check for WI FI symbol on the display it should be alway on 2 Make sure you c...

Страница 25: ...In 1 weather outdoor sensor Up to 7 Wireless hygro thermo sensors optional RF frequency Depend on country version 915Mhz US version RF transmission range 150m Time Related Function Specification Time...

Страница 26: ...km h and knots Wind speed display range 0 112mph 50m s 180km h 97knots Resolution mph m s km h and knots 1 decimal place Speed accuracy 5m s 0 5m s 5m s 6 whichever is greater Display mode Gust Avera...

Страница 27: ...OTE This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection agai...

Отзывы: