The maximal allowable volume depends on the pool volume, the water quality used
to fill the pool. This value must be set by the installer during commissioning.
Vol. Tank = 20L (pH)
This screen allows you to set the volume of the pH tank.
The volume is adjustable from 0 to 25L. To set it just press the
key and choose the
required volume using the keys
and
.
To set the value press the
key. To leave the programme without validating the
mode press the
key.
NOTE: As the PHILEO injects product into the pool, the previously set value is
decreased. When this value reaches 0, the PHILEO’s pump stops. For the pump to
start up again, the user must top up the tank as described above.
If the volume is set at 0, there will be no pH level control.
pH Calibration
This screen is used for probe calibration. This operation must be performed when
starting up the PHILEO for the first time and then repeated about once a month. There
are two solutions supplied with the PHILEO to be used for calibration: a PH7 and a
PH9 solution.
To begin the calibration press the
key. PHILEO then displays CAL. pH7 :x.x ?.
This means the user must plunge the probe into the PH7 solution, wait until the pH
value stabilises and then press on the
key. If the value is correct the calibration
process goes on otherwise the Err. ! message flashs, meaning that the
calibration has to be undertaken once again pressing the
key.
PHILEO then displays CAL. pH9 :x.x ?. The probe must be plunged in the pH9
solution ( after cleaning it) and then press the
key.
If the calibration has been successfully completed, the message Calibration pH
appears on the display. However should the Err. ! message appear, the calibration
should be repeated after checking the solutions and the condition of the probe. If the
problem remains, contact your dealer.