ccei PF10J027 Скачать руководство пользователя страница 7

User manual 

v1.1 

P

H

ILEO 

P

RO 

CCEI 

page

 

 7 

 

 

 
 

SETTINGS MENU 

 

 

 A number of the adjustments listed in this menu can have significant consequences 
on  the  operating  of  the  device  This  menu  is  reserved  for  the  installer  and  is  only 
displayed when the main key is kept pressed during powering on (installer mode). 

 

 
 

SETTINGS 

 

 

This screen provides access to the PHILEO’s different adjustment options. 

To access the settings menu press the  

 and 

 keys. The different displays are as 

follow : 

 

Language 

 

 

This menu allows any one of 8 languages to be chosen for the PHILEO menu : 
French, English, German, Spanish, Italian, Portuguese, Dutch or Czech. 

 

 
 

Reset 

 

 

This screen is used to reinitialise and reset to 0 the various PHILE0 meters.  
The hour meter, the total quantity of injected liquid are reset to 0. 
RESET overrides previous calibrations. 

 

In installer mode the total injected volume since the first operation (or last reset) is 
displayed. 

Содержание PF10J027

Страница 1: ...11 04 2016 CONTENTS TECHNICAL FEATURES 3 INTRODUCTION 4 OPERATION 4 Status menu 4 Settings menu 7 HYDRAULIC CONNECTION 8 pH probe installation 8 Injector installation 8 Installation diagram 9 ELECTRIC...

Страница 2: ...User manual v1 1 PHILEO PRO CCEI page 2...

Страница 3: ...tion filter for the tank containing the solution 1 cable for the connection to the filtration 1 calibration solution at pH7 1 calibration solution at pH9 2 pH probes 1 probe holder 1 injector 1 mainte...

Страница 4: ...a pull down menu for viewing the status of the PHILEO S different variables Moreover this pull down menu is used to access the ADJUSTMENTS menu for adjusting the device THE STATUS MENU Scrolling throu...

Страница 5: ...water pH exceeds the pH set point pH MODE for injecting an alkaline product and hence increasing pool pH The pump starts up when the pH of the water is less than the pH set point ON MODE For injectin...

Страница 6: ...probe calibration This operation must be performed when starting up the PHILEO for the first time and then repeated about once a month There are two solutions supplied with the PHILEO to be used for...

Страница 7: ...s different adjustment options To access the settings menu press the and keys The different displays are as follow Language This menu allows any one of 8 languages to be chosen for the PHILEO menu Fr...

Страница 8: ...pH probe Use a clamp saddle the probe holder and the probe Any screwing must be done with TEFLON PH PROBE INSTALLATION The probe is designed for measuring and checking pool pH by sending information...

Страница 9: ...nto the clamp saddle with TEFLON Clamp saddle to be fitted onto the piping INSTALLATION DIAGRAM The various PHILEO components to be onto the piping of the swimming pool are The pH probe which must be...

Страница 10: ...ires of this connector must be connected to a dry contact of the filtration pump Dry contact means potential free and should be used only for one device If a CCEI filtration box is being used this dry...

Страница 11: ...User manual v1 1 PHILEO PRO CCEI page 11...

Страница 12: ...r The company Bleu Electrique FR 47403521693 declares that the PHILEO product satisfies the safety and electromagnetic compatibility requirements specified in European directives 2006 95 CE and 2004 1...

Отзывы: