CCEI
Limpido Z2
v1.0
Page 9
pH
: 00.00L
This display shows the total volume of injected pH liquid since the first operation;
Prod Cl
: 31h23m
Cell ZLA 60
It shows the total duration of chlorine production since the first operation alternatively with cell model (60m3 in
the above example)
ZLA 25 = 25 m3 cell (« Cell ZLA 30 » can possibly be displayed for 25 m3 cell)
ZLA 50 = 50 m3 cell (« Cell ZLA 60 » » can possibly be displayed for 50 m3 cell)
ZLA 75 = 75 m3 cell (« Cell ZLA 90 » » can possibly be displayed for 75 m3 cell)
P
H
MENU
With this menu you can configurate the pH regulation.
To enter in the pH menu, press the button .
To pull down the menu use the button and . The different displays of this menu are the following:
pH = pH- Dosing
This display allows the selection of the regulation mode. Press the button and select the regulation mode
using the button and .
Different possible modes of regulation are the following:
-
PH- :
to inject PH- and decrease the pool Ph. The pump will therefore run when the pH of the water is
above the Ph set point.
-
PH+
: to inject PH+ and increase the pool Ph. The pump will run when the Ph of the water is lower than
the Ph set point.
-
ON
: to inject PH+ or PH- product permanently and without any regulation. This mode can be used to start
the pump.
-
OFF
: to prevent any injection of the product. This mode can be used during wintering for example.
To validate the mode, press the button . To exit the program without validation press the button .
pH set point = 7.2
With this display you can adjust the Ph set point. To change this value, use the button and . To validate the
value, press the button . To exit the program without validation, press the button .
V/24h=2.0L (pH)
With this display you can adjust the maximum allowable daily injection volume.
Press the button and select the requested maximum volume using the button .
The volume adjustment is in liter. To validate the set volume, press the button . To leave the program without
validation, press the button .
ATTENTION
If this value is left at 0 liter, there will be
no limit
on the volume injected per day. It is therefore
wise to set a value for this parameter.
The maximum allowable value depends on the pool size, the quality of water used to fill the pool. This value
must be set by the technician on starting up.
Tank = 20.0L (pH)