Alternately indications of the system status are possibly displayed: 
 
 

 
The following display shows the status of the pH regulation 

pH- 7.6/7.2 >> 1.5L 

At the left the pH dosing mode is displayed (pH+/pH-/ON/OFF) (see pH Menu), then the measured pH value by 
the  probe  (7.6  in  the  example)  followed  by  the  set  value  (7.2  in  the  example).  A  double  cross  indicates  the 
operation of the dosing pump (a sand glass appears when the pump has to turn on but is waiting for filtration 
or  during  the  breaks.  At  the  right  of  the  screen  the  volume  of  the  injected  liquid  during  the  last  24h  is 
displayed. 
 
A third display shows the status of the ELECTROLYSIS operation; 

THR  04:13/08:30  P 

At  the  left  the  functioning  mode  is  displayed  (ON/OFF/PRG/THR)  (see  Electrolysis  Menu),  then  the  actual 
production period already realized since the beginning of the 24h period (4h13 in the example) followed by the 
expected daily duration (8h30 in the example). 
When the chlorine production is activated, « 

P

 » appears at the right (small p during the breaks between  the 

inversions) followed by « + » or « - » according to the current polarity.  
In  the  « Supervisor »  mode  the  current  chlorine  production  in  g/h  appears  alternately  with  an  hour  counter. 
This value 

is given for indicative purposes

 (calculated according to the current in the cell based on a new 

cell with no consideration of the aging of the product) and can not replace chemical analysis.  
 
 
The following displays are only visible in « Supervisor » mode. They enable to check the intern device counter 
and the estimated concentration of active chlorine.  

  Conduct:1.8mS/cm 

NaCl : 0.9 g/l 

The conductivity and the salt level appear alternately. These values are calculated according to the current in 
the cell, the applied tension on the latter (based on a new one with nop consideratyion of aging) and measured 
temperature. This value is 

for information purpose only

 and can not replace chemical analysis. 

 

Status 

Description 

Filt. Stop 

Filtration pump is stopped. No regulation.  

Temp. 

 

The  current  temperature  is  lower  than  the  minimal  set 
temperature  in  the  electrolysis  menu.  No  treatment  below 
this temperature. 

pH/24>> 

The  max  volume  of  injected  product  per  24h  has  been 
exceeded. Awaiting the next 24h period.  

Tank empty 

The tank is empty. Awaiting filling. 

T° Err  

Temperature measuring error. 

Salt 

 

Too much salt: Check salt level, renew one part of the water 
without salt. See electrolysis section.  

Salt 

 

Lack  of  salt:  Check  salt  level  and  add  some  if  necessary, 
descale  the  cell  by  diluted  acid  (see  electrolysis  section).  
This message may come from a punctual presence of air in 
the cell, due to the filtration pump or air intake in the pipes.  

No Cell 

No detected cell / no communication with the cell. Check cell 
connexion. 

pH >   < 

pH is abnormal (>9,9 or <3,9).  
Check  the  probe.  Restart  calibration.  Check  pH7  and  pH9 
solutions. 

Содержание Limpido Z2 25

Страница 1: ...talling starting up or using this appliance Table of contents features 2 Presentation 2 Installation 3 START UP 6 Maintenance 12 Reference Version Date MPNT0301 V1 0 EN 04 05 2017 Technical Instructions v1 0 Limpido Z2 Salt electrolysis pH regulator ...

Страница 2: ... the environment and the characteristics of the water water conductivity water temperature the volume of the tank to be treated the pH of the water For the security of the installation the electrolyser only produces chlorine when the flow detector signals that water is circulating in the cell In Shock or permanent mode the chlorinator therefore produces chlorine so long as the filtration is operat...

Страница 3: ...n is off the colour depends on water temperature The chlorine production is on the colour depends on water salinity INSTALLATION The Limpido Z2 different elements to be placed on the pool pipework are the following PH probe must be located on the discharge after the filter Ph injector PH or PH is placed just before the outlet The cell is installed between pH probe and pH injector If a heater is us...

Страница 4: ...to the unit Suction strainer to immerse on the tank of correction fluid PH or PH Use the clamp saddles Screw injector on the TEFLON clamp Connect the probe To connect to the pool use clamp saddles probe support and probe All screwings must be done with TEFLON Probe adjustment part on the pipes Use the TEFLON to screw this part on the clamp saddle Clamp saddle to be located on the pipes Electrodes ...

Страница 5: ...e the daily production rate goes from 8h to 2h if the cover is kept closed ELECTRICAL CONNECTION For safety reasons the Limpido Z2 casing must be installed more than 3m 50 from the edge of the pool The casing must be placed on a flat and stable platform It must be powered by 230V single phase 50Hz and protected by a 30mA current device in accordance with applicable regulations Limpido Z2 is fitted...

Страница 6: ...treatment and reliability of the installation the pH of the pool water must be maintained at around 7 A pH between 6 8 and 7 6 is generally deemed to be correct Excessively acidic water pH 6 8 is aggressive for mucus membranes promotes the corrosion of metal parts and can damage PVC liners Excessively basic water pH 7 8 can also be aggressive caustic and significantly reduces the efficiency of the...

Страница 7: ...sponds to a particular problem Colours Flashe Message On the panel Problem Solution Orange No Cell Communication Problem with the panel Check cell connection and its connector Light blue Intern overheating 85 C Cool the cell or install the cell on a fresh place Violet Err T Water temperature measuring error Check connection of the temperature sensor inside the cell Red Salt Very low current Lack o...

Страница 8: ...sed on a new cell with no consideration of the aging of the product and can not replace chemical analysis The following displays are only visible in Supervisor mode They enable to check the intern device counter and the estimated concentration of active chlorine Conduct 1 8mS cm NaCl 0 9 g l The conductivity and the salt level appear alternately These values are calculated according to the current...

Страница 9: ... PH and increase the pool Ph The pump will run when the Ph of the water is lower than the Ph set point ON to inject PH or PH product permanently and without any regulation This mode can be used to start the pump OFF to prevent any injection of the product This mode can be used during wintering for example To validate the mode press the button To exit the program without validation press the button...

Страница 10: ... pH9 x x You need to plunge the probe after rincing in the pH9 solution and press the key If the calibration has been successful the pH Calibration message is shown On the contrary if the message Err appears repeat the calibration procedure after checking the solution and the probe If the problem remains get in touch your installer ELECTROLYSIS MENU With this menu you can configure the electrolysi...

Страница 11: ...often than not expressed in French degrees F If TAS and TH are different use the average value of these two measurements It is important to stress that although very soft water TAS TH 10 F has the advantage that it prevents scaling it is also very corrosive and its pH is very unstable Conversely very hard water 35 F has a pH that is difficult to correct and is highly irritable for skin and causes ...

Страница 12: ... low despite the salt rate being correct you should check the condition of the cell and clean it if scale is visible on the plates To clean it you should block one end and pour in diluted acid HCl at 10 is recommended Allow it to act for a few hours This operation must be carried out with due care and attention and you must conform to the instructions for use relating to the acid that you use PROB...

Страница 13: ...ration Each sensor is characterised by its deviation and slope These two points of measurement must be defined using calibration solutions and sent to the connected instrument As these characteristics tend to drift with use calibration must be carried out regularly Calibration is mandatory in the following cases when installing or after replacing the sensor After every cleaning with a cleaning sol...

Страница 14: ...Serial N Declaration Bleu Electrique SAS FR 47 403 521 693 declares that the Limpido Z2 product fulfils the safety and electromagnetic compatibility requirements of European Directives 2006 95 EC and 2004 108 EEC Emmanuel Baret Marseille the 21 12 2015 Distributor Stamp ...

Отзывы: