background image

Published and distributed by: 
CBS ArcSafe®

 

2616 Sirius Road 
Denton, Texas 76208 

A division of: 
GroupCBS, Inc.® 
P.O. Box 1557 
Gainesville, Texas 76241 

Copyright CBS ArcSafe

®

 2019 

Printed in the United States of America 
Reproduction, adaptation, or translation without prior written permission is prohibited except as is allowed by law. 

More Products by CBS ArcSafe

®

 

RRS-1 – 

Universal Remote Racking System (Rotary)

 

The CBS ArcSafe® RRS-1 is a universal remote racking system capable of remotely installing and removing rotary style draw 
out circuit breakers without requiring any modification to the existing switchgear.  Operation of the simple to use RRS-1 is 
quite intuitive and requires only minimal setup.  When used properly, the RRS-1 allows technicians to remain outside of the 
arc flash boundary during the potentially dangerous racking operation. 
 

RRS-2 – 

Universal Remote Racking System (Non-Rotary)

 

The CBS ArcSafe® RRS-2 is a universal remote racking system capable of remotely installing and removing non-rotary style 
draw out circuit breakers without requiring any modification to the existing switchgear.  Operation of the simple to use 
RRS-2 is quite intuitive and requires only minimal setup.  When used properly, the RRS-2 allows technicians to remain 
outside of the arc flash boundary during the potentially hazardous racking operation. 
 

RRS-3 – 

Application Specific Remote Racking System (Rotary And Non-Rotary)

 

The CBS ArcSafe® RRS-3 product line is made up of various application specific remote breaker racking devices.  Each 
standalone system allows service personnel to remotely install and remove a particular type of circuit breaker safely while 
stationed safely outside of the arc flash boundary during the potentially dangerous operation.  The lightweight and compact 
design of the RRS-3 systems makes them ideal for hard to access areas where space is at a premium. 
 

RRS-4 – 

PLC Based Universal Remote Racking System (Rotary)

 

The CBS ArcSafe® RRS-4 universal remote racking system is an updated PLC based version of the best selling RRS-1.  The 
dual mode, source programmable, PLC based control system offers two different operating modes to choose from based on 
user preference or the application.  The RRS-4 is capable of remotely installing and removing rotary style draw out circuit 
breakers without requiring any modification to the existing switchgear, allowing users to remain outside of the arc flash 
boundary during the potentially hazardous racking operation. 
 

RSA – 

Remote Switch Actuator

 

The CBS ArcSafe® Remote Switch Actuator (RSA) product line is made up of various application specific remote operating 
devices.  These products allow service personnel to remotely perform all aspects of an operation for a particular type of 
electrical equipment from outside the arc flash boundary – reducing or eliminating the possibility of serious injury or death 
resulting from an arc flash. 
 

RSO – 

Remote Switch Operator

 

During a remote operation, the CBS ArcSafe® RSO functions as both the power supply and user interface for the device 
being remotely operated by the user.  When paired with an applicable CBS ArcSafe® device, this portable standalone 
system allows service personnel to remotely perform a racking or switching procedure from outside the arc flash boundary 
– reducing or eliminating the possibility of injury or death resulting from an arc flash 

Содержание RRS-3 WL

Страница 1: ...d in the United States of America Reproduction adaptation or translation without prior written permission is prohibited except as is allowed by law RRS 3 WL Installation and Operation 2616 Sirius Road...

Страница 2: ...y install and remove a particular type of circuit breaker safely while stationed safely outside of the arc flash boundary during the potentially dangerous operation The lightweight and compact design...

Страница 3: ...the user will want to pay particular attention to DANGER Ensure that personnel using this equipment are adequately trained in the operation of the switchgear they are planning to work with that they a...

Страница 4: ...s may interfere with the installation of the remote operating equipment These items may need to be removed or repositioned for proper installation 1 Ensure that the breaker is free from any obstructio...

Страница 5: ...RRS 3 to the breaker by turning the handles of the twist magnets 180 degrees clockwise 6 Extract the racking handle from the WL breaker and pull it out fully until it clicks and locks into place Ensur...

Страница 6: ...Ensure that the breaker s racking handle fits properly into the racking operator on the RRS 3 as shown If it does not align slowly rotate the adapter on the RRS 3 until it aligns properly with the han...

Страница 7: ...this manual for detailed instruc tions 2 Connect the cable from the RSO IV to the motor control box on the RRS 3 3 Turn the power switch on the RSO IV to the ON position 4 Program the settings for the...

Страница 8: ...c situation Note A inch drive torque wrench will be required to perform this adjust ment 1 First remove the racking tool adapter from the RRS 3 by pushing in the locking pin at the base of the adapter...

Страница 9: ...blems which could lead to an arc flash If the RRS does not seem to have enough torque first double check that the breaker is operat ing properly before racking out by hand 5 Take the the higher of the...

Страница 10: ...n the frame The RRS 3 comes pre adjusted from the factory for it s breaker so these adjustments should not normally need to be made To adjust the vertical positioning of the slide assembly 1 Loosen th...

Страница 11: ...on 9 To adjust horizontal positioning of the slide assembly 1 Loosen the two bolts on the angle brackets above the slide assembly as shown 2 Next move the assembly left or right as required 3 Re tight...

Страница 12: ......

Страница 13: ...RRS 3 WL Installation and Operation 11 Notes...

Страница 14: ...RRS 3 WL Installation and Operation 12...

Страница 15: ......

Страница 16: ...that they are correctly stationed outside the arc flash boundary and that they comply with all applicable Federal State Local and In house safety regulations and procedures Attention should be given t...

Отзывы: