background image

SWITCH-MODE BATTERY CHARGER

GENERAL INFORMATION

 The CB51

 switch-mode battery charger has 

been expressly designed for the caravanning and 
boating sector and can automatically charge 12V

0-3

   

lead batteries, with different charging values 
according to the position set using the selector 
positioned inside.

T

 

he battery charger is protected against

overtemperature and the 12V 

 outputs are 

protected against short circuit and polarity inversion.

 

The high frequency switching technology allows 
high performances with small dimensions and 
limited weight.

6 phase automatic charging system

Phase  1: Desulphation

 

-

   

  switching  on  the 

battery charger, only if need , 

 

is  charged  at  15.2V

  until  the  current 

exceeds 2A or for a maximum of 2 hours.

when

ed the battery

 

Phase  2:  Bulk  -

  battery  charging  with  maximum 

current until the end-

charge voltage is 

reached.

of-

 

Phase 3: Absorption  -

 

 

 

end-

charge voltage for the time defined 

by  the  charging  line   with  a  progressive 
current reduction

battery charging at costant

of-

,

 

  until  the  charging  is 

completed.

Note:

  the  end-

charge  voltage  is 

reached only if the battery is efficient.

of-

Phase 6: Refresh   

Bulk

-

The battery is charged 

 

 

voltage  for  a  maximum  time  of  1h;  this 
phase   designed to compensate for 

at the

is

the 

battery  self-discharge. Once  completed, 

 

the 

starts again from  the 

 

phase.

charging 

Float

Phase 4: Float -

 Maintenance charg

 at constant 

voltage for a maximum time of 15 hours. 

ing

h

load 

s

igh 

lead   to  phase 

  starting 

again.

Bulk

Phase 5: Stand-by 

 

 

-

  The  battery  charger  stops 

supplying power. It will switch over to the 

Refresh

  phase only  when  the  battery 

voltage goes under 13

.

 

The position of the selector must be set according 
to the 

ing

most suitable charg

 voltages for the 

type of battery installed.

for led-

 batteries,   position  B  for le d-gel 

acid

on

« »

a

sheet of the battery installed.

I

on

« »

n most cases, the selector can be set

 position  A  

 

batteries and   position  C  for AGM batteries.

on

« »

Nevertheless, it is recommended to consult the data 

DESULPHATION

BULK

ABSORPTION

FLOAT

STAND-BY

REFRESH

Selector on position “A”

Threshold

15,2V

15,2V

15,2V

Max 2h

Max 14,1V

Max 14,4V

Max 14,7V

1,5h

8h

3h

13,5V

13,8V

13,8V

Max 15h

0A

0A

0A

V< 13,0V

14,1V

14,4V

14,7V

Max 1h

Selector on position “B”

Selector on position “C”

7

EN

1

2

3

4

5

6

Содержание CB510-3

Страница 1: ...CB510 3 ELECTRONICS FOR CARAVANNING ed 08 2021 cod 000229 Rev 00 ENERGY LINE EN ISTRUZIONI D USO USER S MANUAL INSTRUCTIONS D EMPLOI BEDIENUNGSANLEITUNG IT DE FR ...

Страница 2: ......

Страница 3: ...upera i 2Ao comunque per un massimodi 2 ore Fase 4 Float Carica di mantenimento a tensione costante per un tempo massimo di 15 ore Un elevato assorbimento dalla batteria comporta la ripartenza dalla fase Bulk Il carica batterie non fornisce più energia e passa alla fase di solo quando la tensione della batteria scende sotto i 13V Fase 5 Stand by Refresh La batteria viene caricata alla tensione di ...

Страница 4: ... sensore temperatura CTCB 3 B C A COLLEGAMENTO 12V 2 Alimentazione 12V 3 1 Alimentazione 12V 4 S Segnale rete 12V COLLEGAMENTO 230V 1 Terra 3 Fase 2 Neutro 1 2 3 S N L Sensore di temperatura da della batteria e dove non possa essereinfluenzatoda altre fonti di calore mod CTCB posizionare inprossimità Se collegato modifica i valori di tensione di carica in funzionedella temperatura rilevata COLLEGA...

Страница 5: ...ezione termica Segnale presenza rete S Tensione di Float IUoU Sì 12V 50 mA 14 V 14 V 1 A 4 B 14 7V C 13 V 13 V 5 A 8 B 13 8V C 3 posizioni A B C Selettore di linea di carica 1 A 0 15A lama DATI TECNICI GENERALI Collegamento alla rete Collegamento alla batteria Temperatura ambiente Direttiva bassa tensione Direttiva compatibilità elettromagnetica 86 Connettore tipo mate n lock 3 poli Connettore tip...

Страница 6: ... alla rete di alimentazione deve essere eseguito rispettando le regole di installazione nazionali Prima di scollegare l apparecchio dalla rete 230V spegnere l interruttoredi sicurezza Installare il carica batterie in un apposito vano asciutto ed aerato il miglior rendimento si ottiene con un installazione verticale vedi figura 2 garantendo una distanza minima di 300mm dalla parte frontale e di 100...

Страница 7: ...ed Note the end charge voltage is reached only if the battery is efficient of Phase 6 Refresh Bulk The battery is charged voltage for a maximum time of 1h this phase designed to compensate for at the is the battery self discharge Once completed the starts again from the phase charging Float Phase 4 Float Maintenance charg at constant voltage for a maximum time of 15 hours ing A h load s igh lead t...

Страница 8: ...temperature sensor CTCB 12V CONNECTION 2 12V supply 4 Net signal 12V S 1 12V supply 3 230V CONNECTION 3 Line 2 Neutral 1 Earth 1 2 3 S N L When is adapted according to the temperature measured by the sensor connected the charging voltage Temperature sensor mod C where it cannot be affected by other heat sources TCB to be placed close to the battery CONNECTION BATTERY TEMPERATURE SENSOR optional 8 ...

Страница 9: ...ef F1 Thermal protection Signal AC power supply S Float voltage IUoU Yes 12V 50 mA 14 V 14 V 1 A 4 B 14 7V C 13 V 13 V 5 A 8 B 13 8V C 3 A B C positions Charg line selector ing 10A 15A car type GENERAL TECHNICAL DATA Mains connection Battery connection Room temperature Low oltage irective v d EMC directive 86 3 way connector mate n lock 4 way connector mate n lock 180 x 140 x 85 mm 1kg 0 50 C Vent...

Страница 10: ...change installation of two air intakes one placed on the top and one on the ottom see figure 2 ensure a working temperature inside the housing not exceeding 50 C b The connection to power supply mains shall be made in accordance with national installation rules Install the battery charger in an appropriate housing dry and ventilated maximum efficiency can be obtained hen the battery charger is ins...

Страница 11: ...sive ducourant NB La fin de charge est uniquement obtenue si la batterie est performante consommation Une élevée de la batterie entraîne le redémarrage à partir de la phase de Bulk Le chargeur de batterie ne fournit plus d énergie et passe Phase 5 Stand by à la phase de Refresh uniquement lorsque la tension de la batterie descend sous les 13 V Phase 4 Float Chargement de maintien à une tension con...

Страница 12: ...e Si celui ci est raccordé il modifie les valeurs de tension de charge en fonction de la température relevée BRANCHEMENT CAPTEUR DE TEMPÉRATURE DE LA BATTERIE en option Les données techniques sont également reportées sur l étiquette interne du couvercle 230V On Off Fuse 230V F2 T A 3 15 Capteur de température de la batterie mod en option CTCB à fixer à proximité de la batterie L 3mt Sélecteur de l...

Страница 13: ...Protection thermique Signal présence de réseau S Tension de Float IUoU Oui 12V 50 mA 14 V 14 V 1 A 4 B 14 7V C 13 V 13 V 5 A 8 B 13 8V C 3 positions A B C Sélecteur de la ligne de charge 1 A 0 15A lam e DONNÉES TECHNIQUES GÉNÉRALES Branchement réseau au Branchement à la batterie Température ambiante Directive basse tension Directive CEM 86 Connecteur de type mate n lock 3 pôles Connecteur de type ...

Страница 14: ...spectant les règles nationales en matière installation d Installer le chargeur de batterie dans un lieu approprié sec et ventilé le meilleur rendements obtient avec ne installation verticale voir l image 2 en garantissant une distance minimum de 300 mm à partir de la artie frontale et de 100 mm à partir de la partie inférieure et supérieure du chargeur de batterie aux environs u p du lieu en quest...

Страница 15: ...Batterie richtig funktioniert Die Batterie wird mit der Bulk Ladespannung für maximal 1 Stunde aufgeladen Diese Phase soll die Selbstentladung der Batterie während einer längeren Nichtnutzung kompensieren Danach startet der Ladevorgang wieder ab der Phase Phase 6 Refresh Float mit einer progressiven Stromreduzierung Das Ladegerät liefert keinen Strom mehr Es tritt in Ph Phase 5 Stand by die ase nu...

Страница 16: ...ler Batterie CTCB 12V ANSCHLUSS 1 12V Versorgung 3 4 Netz Signal 12V S 2 12V Versorgung 230V ANSCHLUSS 3 Außenleiter 1 Erde 2 leiter Neutral 1 2 3 S N L Temperaturfühler Modell CTCB und wo er nicht durch andere Wärmequellen beeinflusst werden kann der in der Nähe von der Batterie su positionieren ist Wenn entsprechend gemessenen angeschlossen verändert er die Ladespannungswerte der Temperatur ANSC...

Страница 17: ...chutz h Außennetzsignal S Float Spannung IUoU Ja 12V 50 mA 14 V 14 V 1 A 4 B 14 7V C 13 V 13 V 5 A 8 B 13 8V C 3 A B C Stellungen Wahlschalter der Ladelinie 1 A 0 15A Typ Auto GENERELLE TECHNISCHE DATEN Anschluss an das Netz Anschluss an die Batterie Raumtemperatur Niederspannungsrichtlinie EMV Richtlinie 86 mate n lock Stecker 3 polig mate n lock Stecker 4 polig 180 x 140 x 85 mm 1kg 0 50 C Belüf...

Страница 18: ...L v D nicht ie Belüftungen auf dem Deckel verstopfen Um einen entsprechenden Luftaustausch im Fach zu garantieren empfehlen wir die Installation von zwei elüftungsöffnungen eine oben und eine unten siehe Abbildung 2 die eine Betriebstemperatur innerhalb des Fachs von nicht über 50 C gewährleisten B Darauf achten dass der Sicherheitsschalter zugänglich ist 230V Bevor das Ladegerät vom Netz den Sich...

Страница 19: ...19 NOTE ...

Страница 20: ...CBE S r l Via Vienna 4 z i Spini settore D 121 Trento 38 Italy Tel 39 0461 991598 Fax 39 0461 960009 cbe cbe it www cbe it ELECTRONICS FOR CARAVANNING ...

Отзывы: