5.6 Shutting Down the CaviBlaster
1.
Adjust the engine speed to idle by pushing on the bottom half of the throttle
control (See Figure 5.1).
2.
Push the PTO handle to the “OFF” position (See Figure 2.3). This will
disengage the pressure pump.
3.
Shut off the engine by turning the ignition key on the control panel to the
“OFF” position (See Figure 5.1).
4.
If using force feed from an alternate source or if using gravity feed, shut off
the supply of water to the pressure pump.
5.
Squeeze the zero-thrust gun trigger to the open or “ON” position (See Figure
5.3) to release the water pressure remaining in the hose(s)
while the zero-
thrust gun is submerged
.
6.
It is now safe to remove the zero-thrust gun from the water.
7.
Flush the system and rinse the power unit with fresh water at the end of the
day.
5.7 – Emergency Shutdown Systems
Figure 5.4 – Control Panel Ignition Key
Page - 24
CaviBlaster 2570-D Operations Manual
For more information please email [email protected] or call 1-(352)275-5319