5.2 Startup of the CaviBlaster
Before starting the CaviBlaster 2570-D power unit, review all safety requirements
found in Section
3.0
SAFETY INFORMATION
. This equipment should only be
operated by individuals who have read and understand the CaviBlaster
Operation and Maintenance Manual.
1)
Verify that the unit has been properly prepared for operation as described
in Section 4.
2)
Connect the zero-thrust gun to the high-pressure hose and unroll sufficient
length of hose to reach the operating location.
3)
Verify that the throttle control is at more than half throttle.
4)
Verify that the PTO lever is in the disengaged position.
5) Apply appropriate hearing protection prior to starting engine.
6)
Turn the ignition start key to the on position and wait for the glow plugs to
heat up. Turn the ignition start key to the start position. If the engine does
not start within 10 seconds, turn the ignition start key to the off position
and wait at least 30 seconds before trying to start again. Once the engine
starts, turn off the ignition start key to the on position.
7) Run the engine at idle speed for a minimum of 20 seconds (20”) at
operating temperatures above 41
◦
F (5
◦
C). For lower operating
temperatures, run at idle speed for a minimum of one minute (1’).
Page - 19
CaviBlaster 2570-D Operations Manual
For more information please email [email protected] or call 1-(352)275-5319
DO NOT THROTTLE UP THE ENGINE UNTIL THE
DIVER IS READY FOR UNDERWATER OPERATION.
The engine must be run at full throttle / full speed. If
partially throttled, the engine will stall, creating an
undesirable running condition for the belt drive system.