PROFINET Configuration
PROFINET protocol handling is done by a PROFINET communication module from HMS (Anybus-IC AB6005).
This module implements real-time (RT) PROFINET I/O in accordance with PROFINET Conformance Class A
(CC-A).
This module is pre-certified if using the default settings of all parameters and is using the original GSD (general
station descriptor) file provided by HMS. At this time, the PROFINET interface reflects HMS default values and
identifiers.
By default, the Anybus module identifies itself as a generic HMS product:
Table 28: Identity Information
P
ARAMETER
V
ALUE
Station Name
(not assigned)
Station Type
ABIC-PRT
Vendor ID
010Ch (HMS Industrial Networks)
Device ID
0008h (Anybus-IC PROFINET)
Electronic Data Sheet (GSD File)
The electronic data sheet (GSD file) is stored in XML format:
GSDML-V2.3-HMS-ABICPRT-20130219.xml
The GSD file features the following characteristics:
●
Three Device Access Points (DAP):
- ABIC_V1 : RT Migration for older firmware.
- ABIC_V15
: RT Migration. Supplied for reverse compatibility with IO Controllers not supporting
extended PROFINET diagnostics
- ABIC_V2 : RT Standard
●
All DAPs support modules with following block sizes: 1, 2, 4, 8, 16, 32, 64, 128 bytes
●
All modules available as input, output and bidirectional (input/output)
●
Each module is associated with exactly one submodule.
In most cases, ABIC_V2 DAP should be selected, with 64 bytes input module.
Input Data
Input Data size : 64 bytes
Table 29 Input (to Remote Device) Data Mapping
B
YTE
#
F
IELD
T
YPE
D
ESCRIPTION
/
V
ALUE
1
Message Format Revision
USINT (0-255)
Revision of the Message Format Definition. Set to 1
2
Message Update Counter
USINT (0-255)
Free running counter; Increments each time the Ethernet/IP
message content is updated inside the MSD.
This is value is independent from the Ethernet/IP packet rate or
RF transactions rate.
3-4
System Address
UINT (0-65535)
5
MSD status:
bit field: