background image

Messenger W 

User Manual 

 

 

 

 

15 

9M02-7000-A001-EN 

Version A 

Action Responses:  
ack text: 

v: r: c 

status text: 

VID(v)-CELL(i s)-REG(r g)-RSSI(#)-GPS(p)-JBUS(j m n)-DATAQ(d e f)-OUTP(a b)-SWX(x)-MSGS(f c)-

VER(v#.#.# date prot modem jbus) 
VID: 

v = vehicle ID 

CELL: 

i = init state 

 

s = current state 

REG: 

r = tower registration 

 

g = data registration 

RSSI: 

# = signal strength 

GPS: 

p = 1 for fix, 0 for no fix 

JBUS: 

j = J1939, J1708, OBD2 

 

 

DATAQ: 

d = count in queue 

 

e = deleted from queue 

 

f = failed 

OUTP: 

 

SWX 
MSGS: 

f = failed 

 

c = count 

VER: 

prot = protocol (Antx, Rastrac, other)  

 

modem = type of modem 

 

jbus = type of bus  

SIM info text: 

VID(v)-MSISDN(s)-ICCID(g)-IMSI(u)-IMEI(p) 

data text: 

VID v-Running: s-52 RPM: r-x Hours: h- CoolTemp: x-Battery -OilPress -Odometer o 

generator control text: 

 

 

 

Содержание Messenger W

Страница 1: ...Messenger W User Manual 9M02 7000 A001 EN ...

Страница 2: ...ent nor as to the fitness merchantability or sustainability of any Cattron products for any specific or general uses Cattron Holdings Inc or any of its affiliates or agents shall not be liable for incidental or consequential damages of any kind All Cattron products are sold pursuant to the Terms and Conditions of Sale a copy of which will be furnishedupon request When used as a tradename herein Ca...

Страница 3: ...ore and Forward Data Queue 6 1 4 Specifications 6 2 Installation and Setup 7 2 1 Installation Steps 7 2 2 Unpacking the Equipment 7 2 3 Mounting the Equipment 7 2 3 1 EEC Thermoplastic Enclosure 8 2 4 Mounting the Antenna 8 3 LED States 9 4 Channels 11 4 1 Defined Channels 11 4 2 Channel Data 12 5 SMS Text Commands 14 5 1 Command Syntax 14 6 Diagrams 16 7 Technical Support 18 ...

Страница 4: ...y platform It supports monitoring of data values from onboard physical IO Features The hardware feature set of this platform includes the following Battery backed on power fail Power fail detection Three Digital Inputs user configurable to accept a voltage or ground input One Digital Output transistor closures to ground One Analog Input 10 bit user configurable for V or mA input 3G or LTE cellular...

Страница 5: ...otification events Notification events are based on rules set by the user and each event can generate an immediate report Telemetry includes cellular data connectivity to host server or SMS messaging direct to user Monitored data values are mapped to fixed channels in the Messenger W A channel defines a set of attributes for the monitored data for doing calculations alarm detection data formatting...

Страница 6: ...sages generated contain data others serve simply as notification that a particular event has occurred 1 3 2 Store and Forward Data Queue There are several scenarios where a message may not be deliverable network down host server down and poor connectivity to name a few In the event that a message cannot be delivered it is stored in memory and is continually re sent until it is properly acknowledge...

Страница 7: ...ave a service loop just below the antenna connector 3 Connect Main Power 4 Connect Field Signals digital analog Modbus to the appropriate wire Wiring information can be found in Figure 2 and Figure 3 in the Diagrams section 2 2 Unpacking the Equipment The Messenger W is shipped with the following The Messenger W electronics in a Deutsch thermoplastic enclosure or a board only product A Cellular an...

Страница 8: ...ed with a magnetic or a screw mount base In general the antenna should be mounted with an unobstructed view of the sky If the antenna is mounted outside and may be subject to lightning a surge arrestor can be inserted between the antenna and the Messenger W If the antenna is mounted inside it should be located near a window CAUTION SERVICE LOOPS SHOULD BE PROVIDED FOR THE ANTENNA CABLING NEAR THE ...

Страница 9: ...very second Boot Loader Mode all other LEDs off On or Off Solid System Failure LED 2 RED Cell Registration State Rate Definition Blink Rapid blink then off OK Rx Tx Activity with CELL Modem Blink 1 blink every second Not Registered Check APN Verify valid cellular account Off Solid OK Registered LED 3 RED Cell Status State Rate Definition Blink 10 blinks every second No SIM card or communications f...

Страница 10: ...every second Lithium Coin Cell battery is low or RTC has stopped On Solid If DIN1 DIN2 DIN3 or DIN4 are configured as pulse counter inputs this LED will light when any input is activated off when all inputs are idle Off Solid No Faults LED 8 RED CELL Signal Strength Rate Definition OFF Not registered or not detectable 1 blink 1 2 sec pause signal strength 6 weak 2 blinks 1 2 sec pause signal stren...

Страница 11: ...ve device 4 1 Defined Channels The following channels are predefined in the Messenger W The wiring for some of these channels can be found in Figure 2 and Figure 3 in the Diagrams section Table 4 1 Predefined Channels Channel Number Channel Name Type Description Start Digital Channels data values are 0 or 1 1 Cell Digital System Status of cellular modem operation 1 fault 0 normal 2 Comm Digital Sy...

Страница 12: ... configured for 0 1 VDC 0 5 VDC 0 10 VDC or 0 20 mA 154 Daily Flow Volume Derived Accumulated flow volume for the day flow rate from ADC input 155 Running Flow Volume Derived Accumulated flow volume since last volume reset flow rate from ADC input 4 2 Channel Data All values read from physical IO or from a Modbus slave device are continually updated and tested as defined by the configuration param...

Страница 13: ... rate These channels have an extended data set Extended Data Set For the analog channel Daily total volume available on separate channel 154 Continuous running total volume available on separate channel 155 For the digital channels Flow rate Daily total volume Continuous running total volume The Messenger W also maintains a set of daily data The daily data set is a separate set of current and max ...

Страница 14: ...Action Description Response 1 Generate on demand standard report to host server ack report 2 Return status to sender status 3 Force cell modem reset ack 4 Clear all stored data records ack 5 Return Cell config to sender cell config 6 Force digital output 1 on ack 7 Force digital output 1 off ack 8 Generate on demand end of day report to host server ack report 10 Return a subset of channel data val...

Страница 15: ...nt state REG r tower registration g data registration RSSI signal strength GPS p 1 for fix 0 for no fix JBUS j J1939 J1708 OBD2 m n DATAQ d count in queue e deleted from queue f failed OUTP A B SWX MSGS f failed c count VER prot protocol Antx Rastrac other modem type of modem jbus type of bus SIM info text VID v MSISDN s ICCID g IMSI u IMEI p data text VID v Running s 52 RPM r x Hours h CoolTemp x...

Страница 16: ...er W User Manual 16 9M02 7000 A001 EN Version A 6 Diagrams These figures provide some additional details concerning the wiring and LED locations in the Messenger W Figure 2 LED Locations and Wiring Information ...

Страница 17: ...Messenger W User Manual 17 9M02 7000 A001 EN Version A Figure 3 Messenger W Wiring Details ...

Страница 18: ...senger W User Manual 18 9M02 7000 A001 EN Version A 7 Technical Support For remote and communication control systems support parts and repair or technical support visit us online at www cattron com contact ...

Страница 19: ...e information provided in this document is subject to change without notice Cattron Support For remote and communication control systems support parts and repair or technical support visit us online at www cattron com contact Cattron North America Inc 655 N River Rd NW Suite A Warren OH 44483 ...