background image

CANplus

TM

 CP1000 

Installation Manual 

 

 

 

13 

9M01-1000-A401-EN 

Revision B 

6.2  Industry Canada Certification 

 

Note: 

These statements are required to be listed in both English and French Languages

 

 
This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following 

two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, 

including interference that may cause undesired operation of the device. 
Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de 

licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de 

brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage 

est susceptible d'en compromettre le fonctionnement. 
 
Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and 

maximum (or lesser) gain approved for the transmitter by Industry Canada. To reduce potential radio interference 

to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power 

(e.i.r.p.) is not more than that necessary for successful communication.  
Conformément à la réglementation d'Industrie Canada, le présent émetteur radio peut fonctionner avec une 

antenne d'un type et d'un gain maximal (ou inférieur) approuvé pour l'émetteur par Industrie Canada. Dans le but 

de réduire les risques de brouillage radioélectrique à l'intention des autres utilisateurs, il faut choisir le type 

d'antenne et son gain de sorte que la puissance isotrope rayonnée équivalente (p.i.r.e.) ne dépasse pas l'intensité 

nécessaire à l'établissement d'une communication satisfaisante. 
 
This equipment complies with the ICES RF radiation exposure limits set forth for an uncontrolled environment. 

This equipment should be installed and operated with a minimum distance of 20 cm between the radiator and any 

part of the human body.   
Cet équipement est conforme aux limites d'exposition aux radiations ICES définies pour un environnement non 

contrôlé . Cet équipement doit être installé et utilisé à une distance minimale de 20 cm entre le radiateur et une 

partie de votre corps. 
 

 

 

 

Содержание CANplus CP1000

Страница 1: ...CANplusTM CP1000 Installation Manual 9M01 1000 A401 EN ...

Страница 2: ... nor as to the fitness merchantability or sustainability of any Cattron products for any specific or general uses Cattron Holdings Inc or any of its affiliates or agents shall not be liable for incidental or consequential damages of any kind All Cattron products are sold pursuant to the Terms and Conditions of Sale a copy of which will be furnishedupon request When used as a tradename herein Cattr...

Страница 3: ...ing Templates 5 3 Connector Pinouts 8 3 1 D21 to Engine Pinout 8 3 2 D31 IO Pinout 9 4 Typical Wiring 10 4 1 Power and Ground 10 4 2 ECU Power Out 10 4 3 Starter Power Out 10 4 4 Resistive Senders 10 4 5 CAN Bus Termination 10 5 Testing 11 6 Certifications 12 6 1 FCC Part 15 Certification 12 6 2 Industry Canada Certification 13 7 Technical Support 14 ...

Страница 4: ...s manual s target audience is professional installers for Engine Distributors and OEMs of engine driven machines The engine manufacturer specific application information should be followed for any detailed or specific requirements Cattron sales and technical support are available at www cattron com contact to discuss specialized requirements or custom applications ...

Страница 5: ...ated so the panel does not hit any adjacent structure during operation 2 1 AluFlex Panels AluFlex panel enclosures are constructed from extruded aluminum and powder coated for durability The faceplate is aluminum or powder coated galvanized steel and the backplate is powder coated galvanized steel The enclosure is splash proof and includes condensation drain holes in the bottom AluFlex panel isola...

Страница 6: ...CANplusTM CP1000 Installation Manual 6 9M01 1000 A401 EN Revision B ...

Страница 7: ...CANplusTM CP1000 Installation Manual 7 9M01 1000 A401 EN Revision B ...

Страница 8: ...nout Pin Signal Comment Pin Signal Comment A Pre Heat 1 A System Voltage M Aux IN 2 Active Low B B N Temp SW Active Low Normally Open C Sender Return P Oil PSI Sender System Voltage 0 750 Ω D Starter 10 A System Voltage R E GND S Pulse2 Tach System Voltage F CAN Shield T Oil PSI SW Active Low Normally Closed G ECU Solenoid 10 A System Voltage U CAN Low H Temp Sender System Voltage 0 750 Ω V CAN Hi...

Страница 9: ...ucer Power 2 1 A System Voltage 4 Switched In 4 Active Low 20 Pulse In 1 5 Switched In 5 Active Low 21 Pulse Gnd 6 Switched In 6 Active Low 22 Pulse In 2 7 Isolated Power In 1a 20 A 23 E Stop Input Normally Grounded 8 Isolated Power In 1b 24 4 20 mA In 9 Isolated Power Out 1a 20 A 25 4 20 mA In 10 Isolated Power Out 1b 26 4 20 mA In 11 Isolated Power Out 2 10 A 27 4 20 mA In 12 Isolated Power In 2...

Страница 10: ...lays that have this protection suppression diode built in The protection suppression diode must have sufficient voltage ratings to survive and sufficiently suppress these negative voltage surges Cattron recommends a 1N4001 diode Cattron sells a spike suppressing diode kit Part Number 630 4007 77 4 4 Resistive Senders The Resistive Sender connections send system voltage out to the sender to obtain ...

Страница 11: ...ing fault on failure 3 Verify fuel run stop solenoid or ECM energizes 4 Fuel solenoid should be powered for 10 to 30 seconds when the key is turned on a The ECM should send CAN bus data as soon as the self test completes b Verify engine cranks when the key is turned to start check all connections on failure 5 If the engine does not start check the fuel lines and bleed if necessary 6 Verify gauges ...

Страница 12: ...t installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interfer...

Страница 13: ... Canada To reduce potential radio interference to other users the antenna type and its gain should be so chosen that the equivalent isotropically radiated power e i r p is not more than that necessary for successful communication Conformément à la réglementation d Industrie Canada le présent émetteur radio peut fonctionner avec une antenne d un type et d un gain maximal ou inférieur approuvé pour ...

Страница 14: ...CP1000 Installation Manual 14 9M01 1000 A401 EN Revision B 7 Technical Support For remote and communication control systems support parts and repair or technical support visit us online at www cattron com contact ...

Страница 15: ...ment the information provided in this document is subject to change without notice Cattron Support For remote and communication control systems support parts and repair or technical support visit us online at www cattron com contact Cattron North America Inc 655 N River Rd NW Suite A Warren OH 44483 ...