Alarm codes

Description

Solution

00

0

Microcontroller memory alarm

Contact technician

I00

32

Microcontroller memory alarm

Contact technician

I01

33

Short circuit caused by one of the two 

motors

Check cause of short circuit and remove 

it

I02

34

Short circuit before motor control

Contact the technician (board probably 

damaged)

I03

35

Failed capacitor charging

Contact technician (replace the board)

I04

36

Temperature threshold exceeded

Ventilate plant room

I05

37

Blower current limit exceeded

Check efficiency of blower (shutdown or 

excessive resistance)

I07

39

Maximum voltage on capacitors 

exceeded

Check mains voltage max. 260V

S08

40

Centrifuge short circuit

Remove short circuit

S09

41

Short circuit of card in centrifuge 

outlet

Replace the board

S10

42

Instantaneous centrifuge current limit 

exceeded

Eliminate siphons in pipes or check 

efficiency of the centrifuge (shutdown or 

excessive resistance)

S11

43

Delayed centrifuge current limit 

exceeded

Eliminate siphons in pipes or check 

efficiency of centrifuge (shutdown or 

excessive resistance)

I13

45

Amalgam reader disconnected

Connect amalgam sensor

I14

46

95% of amalgam level exceeded

Replace amalgam container asap

I15

47

100% of amalgam level exceeded

Replace amalgam container

I16

48

Vacuum sensor tube disconnected

Connect vacuum tube to centrifuge

I17

49

Open thermal pad (Centr. Sep.)

Restore temperature in plant room

ALARMS DESCRIPTION

Содержание TURBO SMART HP

Страница 1: ...WE LOVE WHAT WE DO English Instruction Manual TURBO SMART HP...

Страница 2: ...2...

Страница 3: ...maintenance 12 Extraordinary maintenance 13 Instructions for adjusting some parameters in the menus of Smart aspirators 15 Instructions for configuration of WIFI wireless communication 24 Alarms desc...

Страница 4: ...E standard Parameters r 1 5 background noise 34 dB A Instrument Br el Kjaer type 2232 GENERAL OPERATION DATA 50 60 HZ TURBO SMART HP SUCTION UNIT Model Turbo Smart HP Nominal voltage 230 V Nominal fr...

Страница 5: ...ly startup operation and maintenance of your Turbo Smart HP suction Updated manuals are available from our website www cattani it We recommend you refer to these especially for the latest safety updat...

Страница 6: ...ng suitable tools The suction unit must be placed in a clean area away from heat sources humidity and dust Ambient temperature of the technical room must be below 5 C and not above 35 C Turbo Smart HP...

Страница 7: ...other end of the tube shall be connected to the antibacterial filter 5 passing preferably through a silencer 5a supplied with the aspirator The hot air coming from the antibacterial filter must be con...

Страница 8: ...the floor for a few metres then rise with a flexible tube up to the centrifugal separator fig B page 30 the fluid enters the suction unit When assembly is completed connect the power cable to the elec...

Страница 9: ...iping the two or three suction units in parallel shall be connected in parallel also to the permissive 12 incoming from the various dental units While installing the suction units in parallel make sur...

Страница 10: ...rrectly maintenance operations with Puli Jet Plus New A Pulse Cleaner B and antifoaming disinfectant tablets C The suction assembly is made of two blowers in series STAGE I and STAGE II that through t...

Страница 11: ...ed 09 2021 EN G LISH The Turbo Smart HP can be ordered complete with the Hydrocyclon ISO 18 amalgam separator The amalgam separator always comes with the operation and maintenance manual ISO AMALGAM...

Страница 12: ...cian Every night aspiration of Puli Jet Plus New disinfectant solution with antiscaling agent A using Pulse Cleaner B Before going near the suction unit remove the power Place the antifoaming disinfec...

Страница 13: ...pour the disinfectant in manually tilt the machine repeatedly so that the liquid can reach all contaminated parts EXTRAORDINARY MAINTENANCE RECOMMENDED INSPECTIONS EVERY 12 MONTHS Check the maximum te...

Страница 14: ...e 14 RECOMMENDED INSPECTIONS EVERY 10 000 HOURS Rubber parts O Rings bellows seals must be replaced every time a part that affects seal is disassembled Replace motor bearings and vibration dampeners I...

Страница 15: ...he main menu appears CONTROL MENU A2 This menu shows number of times the machine was switched on total switched on hours number of suction unit activations actual hours of suction unit use operation h...

Страница 16: ...0 Hours operation in relation to frequency Fan Cycles 00000 Number of activations of control unit cooling fan DRIVE STATUS This menu can be accessed without Password here you can read useful informati...

Страница 17: ...e User Parameters menu is 0000123000 The password for the System Parameters Setup menu is 0000456000 KEYING IN AND ENTERING THE PASSWORD From the CATTANI S p A menu press the arrow then the arrow the...

Страница 18: ...the same procedure to enter the password 0000456000 and access the changes of the System Parameters Setup menu INVERTER STATUS MENU This menu is visible without entering a password Its function is to...

Страница 19: ...LISH Centrifugal separator current System temperature Maximum temperature detected can be reset with code 19404 in menu drive commands Maximum detected temperature Bus voltage Maximum bus voltage reco...

Страница 20: ...Shows maximum vacuum level set Press Enter to change use the arrows to set the desired value Press Enter to confirm change I I Language You can select Italian 0 English 1 French 2 Spanish 3 German 4 a...

Страница 21: ...to highlight the parameters you want to change Press Enter to activate the cursor use the arrows to set the desired value Press Enter to confirm change All the parameters can be adjusted Minimum vacu...

Страница 22: ...level not active Surgical vacuum level not active Maximum blower frequency for surgical vacuum level not active Blower current limit for surgical vacuum level not active Switch off delay max 300 S Pum...

Страница 23: ...23 cod ed 09 2021 EN G LISH Options Used Enables or disables reading of amalgam sensor 0 without amalgam separator 1 with amalgam separator Commands to inverter Reserved for factory settings...

Страница 24: ...search I Once the search is complete it will show all available Wi Fi networks close to the device Select a network using the UP DOWN arrows then confirm I A couple of seconds after you have selected...

Страница 25: ...Menu using the continue up to arrows Menu WI FI M5 Now the WI FI menu shows in S0 the non changeable IP address dynamic IP In the WI FI menu to control the selected network n SSID M5 S1 In Menu M5 S2...

Страница 26: ...ke sure that M5 S5 is set to 2 Make sure that DHCP is set to 1 Now press the left arrow and then ESC to back to Main menu A1 where you can see WI FI ON When communication with a PC is on the display w...

Страница 27: ...citors exceeded Check mains voltage max 260V S08 40 Centrifuge short circuit Remove short circuit S09 41 Short circuit of card in centrifuge outlet Replace the board S10 42 Instantaneous centrifuge cu...

Страница 28: ...for the latest safety updates Smart systems are AEE equipment thus subject to WEEE Waste Electrical and Electronic Equipment Directive regulations During transport and storage the packaged equipment c...

Страница 29: ...er When the users need to dispose of this equipment they shall contact the manufacturer and follow the system that the manufacturer has adopted to enable separate collection of the equipment after its...

Страница 30: ...30 cod ed 09 2021 SAME LEVEL INSTALLATION LEVEL BELOW INSTALLATION ASSEMBLY SCHEME...

Страница 31: ...31 cod ed 09 2021 EN G LISH TURBO SMART HP CIRCUIT Fig C ELECTRICAL CONNECTIONS...

Страница 32: ...nlet open 48 52 330 338 8 5 8 8 1 3 1 5 7 7 5 Suction inlet closed To verify the correct operation of a variable frequency suction unit some dynamic type tests can be carried out such as the following...

Страница 33: ...33 cod ed 09 2021 EN G LISH EXAMPLES OF PIPING Fig E E TURBO SMART HP Fig F...

Страница 34: ...34 cod ed 09 2021 Fig G TURBO SMART HP EXPLODED VIEW...

Страница 35: ...35 cod ed 09 2021 EN G LISH Fig H CENTRIFUGAL SEPARATOR 023764 EXPLODED VIEW...

Страница 36: ...36 cod ed 09 2021 Fig I UNI JET 75 SX 015663 EXPLODED VIEW...

Страница 37: ...37 cod ed 09 2021 EN G LISH Fig L UNI JET 75 DX 015664 EXPLODED VIEW...

Страница 38: ...38 cod ed 09 2021 Fig M AMALGAM SEPARATOR 043396 EXPLODED VIEW...

Страница 39: ...39 cod ed 09 2021 EN G LISH Fig N CONTROL UNIT 023764 EXPLODED VIEW...

Страница 40: ...40 cod ed 09 2021 Fig O TURBO SMART HP DIMENSIONS...

Страница 41: ...41 cod ed 09 2021 EN G LISH Fig P TURBO SMART HP DIMENSIONS...

Страница 42: ...42 cod ed 09 2021 TURBO SMART HP DIMENSIONS Fig Q...

Страница 43: ...43 cod ed 09 2021 EN G LISH...

Страница 44: ...arch this enables us to apply the latest technology to all of our products and solutions We enhance performance electronic and information technology enable us to enhance the performance and reliabili...

Отзывы: